Chapter 8: Diagnostic and Repair Procedures
8-11
Error Number 117
This error condition indicates there is a Host or MODBUS Serial
Interface Framing Error or Reply Timeout (timeout must be a
minimum of 15 seconds.) Most communication errors are caused
by excessive noise.
Check the termination of RX input.
Check the baud rate (S2-1)
•
S2-1 CLOSED = 9600
•
S2-1 OPEN = 1200
Check the character size (S2-5)
•
S2-5 CLOSED = 8 bit, 1 stop.
•
S2-5 OPEN = 7 bit, 2 stop
Check the RX with a Voltmeter. Perform the check when the line is
in a steady state (No transmission).
RS-485
•
RX(-A) = GND
•
RX(+B) = +5VDC
RS-232
•
RX(-A) = -12VDC to -4VDC
•
RX(+B) = GND
Error Number 118
This error indicates a host or Modbus serial RX overrun error. The
baud rate may be set incorrectly.
To correct this error, check the baud rate setting which is controlled
by dip switches S2-1 and S2-4:
•
S2-1 closed = 9600 baud
•
S2-2 open = 1200 baud
Industrial Dynamics Company, Ltd. ©
Form
40256-0600
Summary of Contents for FT-70c
Page 1: ...FT 70c Service and Technical 40256 0600 Reference Manual for Can Inspection...
Page 14: ...Table of Contents XIII Industrial Dynamics Company Ltd Form 40256 0600...
Page 21: ...FT 70 Fill Level Inspector Service Manual 1 2 Industrial Dynamics Company Ltd 40256 0600...
Page 33: ...FT 70 Fill Level Inspector Service Manual 1 14 Industrial Dynamics Company Ltd 40256 0600...
Page 35: ...FT 70 Fill Level Inspector Service Manual 2 2 Industrial Dynamics Company Ltd 40256 0600...
Page 39: ...FT 70 Fill Level Inspector Service Manual 2 6 Industrial Dynamics Company Ltd 40256 0600...
Page 41: ...FT 70 Fill Level Inspector Service Manual 3 2 Industrial Dynamics Company Ltd 40256 0600...
Page 69: ...FT 70 Fill Level Inspector Service Manual 3 30 Industrial Dynamics Company Ltd 40256 0600...
Page 71: ...FT 70 Fill Level Inspector Service Manual 4 2 Industrial Dynamics Company Ltd 40256 0600...
Page 139: ...FT 70 Fill Level Inspector Service Manual 5 44 Industrial Dynamics Company Ltd 40256 0600...
Page 141: ...FT 70 Fill Level Inspector Service Manual 6 2 Industrial Dynamics Company Ltd 40256 0600...
Page 183: ...FT 70 Fill Level Inspector Service Manual 7 2 Industrial Dynamics Company Ltd 40256 0600...
Page 225: ...FT 70 Fill Level Inspector Service Manual 9 2 Industrial Dynamics Company Ltd 40256 0600...
Page 233: ...FT 70 Fill Level Inspector Service Manual 10 2 Industrial Dynamics Company Ltd 40256 0600...
Page 243: ...FT 70 Fill Level Inspector Service Manual 10 12 Industrial Dynamics Company Ltd 40256 0600...