FT-70 Fill Level Inspector Service Manual
4-14
Aligning the Down Can Sensor
The Down Can Sensor is mounted on separate brackets that are
attached on the bottom of the inspection head and aligned to the
head centerline.
Figure 4-7.
Aligning the Down Can Sensor.
1.
The mounting brackets themselves are not adjustable, however
the sensor height can be adjusted by positioning it in the
proper mounting hole within the block.
3.
If you will not be performing further alignment procedures,
turn on the Safety Interlock Switch to reactivte the X-ray
Generator. See
Chapter 5: The Safety Interlock Switch
.
Drawing Can Sizes
32293
8 , 10,12, 16, 24 oz.
4
1
3
2
No. Description
1 Sensor beam
2 Sensor Emitter
3 Sensor Receiver
4 Container Travel
then refer to the
FT-50 and FT-70 Installation and Service
to locate the drawing of your bracket. Use the
information in the drawing to determine the proper position for
o
the sensor.
2.
To determine the proper sensor height, align fill level inpection
beam first (and perform Fill Level Optimization if needed) and
Industrial Dynamics Company, Ltd. ©
40256-0600
Summary of Contents for FT-70c
Page 1: ...FT 70c Service and Technical 40256 0600 Reference Manual for Can Inspection...
Page 14: ...Table of Contents XIII Industrial Dynamics Company Ltd Form 40256 0600...
Page 21: ...FT 70 Fill Level Inspector Service Manual 1 2 Industrial Dynamics Company Ltd 40256 0600...
Page 33: ...FT 70 Fill Level Inspector Service Manual 1 14 Industrial Dynamics Company Ltd 40256 0600...
Page 35: ...FT 70 Fill Level Inspector Service Manual 2 2 Industrial Dynamics Company Ltd 40256 0600...
Page 39: ...FT 70 Fill Level Inspector Service Manual 2 6 Industrial Dynamics Company Ltd 40256 0600...
Page 41: ...FT 70 Fill Level Inspector Service Manual 3 2 Industrial Dynamics Company Ltd 40256 0600...
Page 69: ...FT 70 Fill Level Inspector Service Manual 3 30 Industrial Dynamics Company Ltd 40256 0600...
Page 71: ...FT 70 Fill Level Inspector Service Manual 4 2 Industrial Dynamics Company Ltd 40256 0600...
Page 139: ...FT 70 Fill Level Inspector Service Manual 5 44 Industrial Dynamics Company Ltd 40256 0600...
Page 141: ...FT 70 Fill Level Inspector Service Manual 6 2 Industrial Dynamics Company Ltd 40256 0600...
Page 183: ...FT 70 Fill Level Inspector Service Manual 7 2 Industrial Dynamics Company Ltd 40256 0600...
Page 225: ...FT 70 Fill Level Inspector Service Manual 9 2 Industrial Dynamics Company Ltd 40256 0600...
Page 233: ...FT 70 Fill Level Inspector Service Manual 10 2 Industrial Dynamics Company Ltd 40256 0600...
Page 243: ...FT 70 Fill Level Inspector Service Manual 10 12 Industrial Dynamics Company Ltd 40256 0600...