Chapter 4: Configuring the FT-70 for Operation
4-19
Configuring the X-ray Threshold
The X-ray Threshold defines the x-ray radiation count that is the
dividing line between accepting or rejecting a container during fill
level inspection.
Before you configure the X-ray Threshold, you must have aligned
the Fill Level Inspection Beam properly as explained in
Aligning
the Fill Level Inspection Beam
.
1.
Remove the FT-70 cover and set dip switch S1-1 to the proper
setting for the type of fill level inspection you want to perform:
•
Overfill Inspection: S1-1 = open
•
Underfill Inspection: S1-1 = closed
2.
Replace the cover.
3.
Open the radiation source shutter by pulling the actuating rod
out until it stops.
4.
Start the conveyor and run it at the maximum production
speed.
5.
If your FT-70 is not in the Calibrate Mode, Press Key 5 until you
reach SYSTEM DISPLAY and then press the Arrow Key to
enter the Calibrate Mode.
6.
Press Key 1 until GAMMA THRESHOLD appears.
7.
Place a properly filled sample production container on the
conveyor far enough upstream of the FT-70 so that it does not
slip on the chain and is positioned correctly as it passes
through the inspection tunnel.
8.
Record the value that appears in the X-ray Threshold display.
9.
Repeat the previous two steps four more times and then
average the value to get the average good count (GC).
a
b
c
d
e
+
+
+
+
(
)
5
--------------------------------------------
GC
=
Industrial Dynamics Company, Ltd. ©
Form
40256-0600
Summary of Contents for FT-70c
Page 1: ...FT 70c Service and Technical 40256 0600 Reference Manual for Can Inspection...
Page 14: ...Table of Contents XIII Industrial Dynamics Company Ltd Form 40256 0600...
Page 21: ...FT 70 Fill Level Inspector Service Manual 1 2 Industrial Dynamics Company Ltd 40256 0600...
Page 33: ...FT 70 Fill Level Inspector Service Manual 1 14 Industrial Dynamics Company Ltd 40256 0600...
Page 35: ...FT 70 Fill Level Inspector Service Manual 2 2 Industrial Dynamics Company Ltd 40256 0600...
Page 39: ...FT 70 Fill Level Inspector Service Manual 2 6 Industrial Dynamics Company Ltd 40256 0600...
Page 41: ...FT 70 Fill Level Inspector Service Manual 3 2 Industrial Dynamics Company Ltd 40256 0600...
Page 69: ...FT 70 Fill Level Inspector Service Manual 3 30 Industrial Dynamics Company Ltd 40256 0600...
Page 71: ...FT 70 Fill Level Inspector Service Manual 4 2 Industrial Dynamics Company Ltd 40256 0600...
Page 139: ...FT 70 Fill Level Inspector Service Manual 5 44 Industrial Dynamics Company Ltd 40256 0600...
Page 141: ...FT 70 Fill Level Inspector Service Manual 6 2 Industrial Dynamics Company Ltd 40256 0600...
Page 183: ...FT 70 Fill Level Inspector Service Manual 7 2 Industrial Dynamics Company Ltd 40256 0600...
Page 225: ...FT 70 Fill Level Inspector Service Manual 9 2 Industrial Dynamics Company Ltd 40256 0600...
Page 233: ...FT 70 Fill Level Inspector Service Manual 10 2 Industrial Dynamics Company Ltd 40256 0600...
Page 243: ...FT 70 Fill Level Inspector Service Manual 10 12 Industrial Dynamics Company Ltd 40256 0600...