FT-70 Fill Level Inspector Service Manual
4-20
10.
To complete the configuration you must follow the appropriate
procedure based on the type of fill level inspection you will be
performing:
•
If you will be performing overfill inspection proceed to
Setting the Overfill X-ray Threshold
.
•
If you will be performing underfill inspection proceed to
Setting the Underfill X-ray Threshold
.
Setting the Overfill X-ray Threshold
1.
Place a sample production container that is overfilled by
approximately 3mm to 5mm on the conveyor far enough
upstream of the FT-70 so that it does not slip on the chain and
is positioned correctly as it passes through the inspection
tunnel.
2.
Record the X-ray Counts value that appears in the X-ray
Threshold display.
3.
Repeat the previous two steps four more times and then
average the value to get the average bad count (BC).
4.
Use the following equation to determine the Overfill X-ray
Threshold.
5.
Press Key 1 until you reach GAMMA THRESHOLD and use
the Arrow Key to enter the Overfill X-ray Threshold Value (T)
you calculated in step 4.
6.
If you are finished configuring the FT-70, press Key 5 until you
reach SYSTEM DISPLAY and then press the Arrow Key to
return to the Operate Mode.
where:
GC
= Average Good Counts (step 9).
BC
= Average Bad Counts (step 3).
T
= Overfill X-ray Threshold.
a
b
c
d
e
+
+
+
+
(
)
5
--------------------------------------------
BC
=
GC
BC
+
(
)
2
----------------------------
T
=
Industrial Dynamics Company, Ltd. ©
40256-0600
Summary of Contents for FT-70c
Page 1: ...FT 70c Service and Technical 40256 0600 Reference Manual for Can Inspection...
Page 14: ...Table of Contents XIII Industrial Dynamics Company Ltd Form 40256 0600...
Page 21: ...FT 70 Fill Level Inspector Service Manual 1 2 Industrial Dynamics Company Ltd 40256 0600...
Page 33: ...FT 70 Fill Level Inspector Service Manual 1 14 Industrial Dynamics Company Ltd 40256 0600...
Page 35: ...FT 70 Fill Level Inspector Service Manual 2 2 Industrial Dynamics Company Ltd 40256 0600...
Page 39: ...FT 70 Fill Level Inspector Service Manual 2 6 Industrial Dynamics Company Ltd 40256 0600...
Page 41: ...FT 70 Fill Level Inspector Service Manual 3 2 Industrial Dynamics Company Ltd 40256 0600...
Page 69: ...FT 70 Fill Level Inspector Service Manual 3 30 Industrial Dynamics Company Ltd 40256 0600...
Page 71: ...FT 70 Fill Level Inspector Service Manual 4 2 Industrial Dynamics Company Ltd 40256 0600...
Page 139: ...FT 70 Fill Level Inspector Service Manual 5 44 Industrial Dynamics Company Ltd 40256 0600...
Page 141: ...FT 70 Fill Level Inspector Service Manual 6 2 Industrial Dynamics Company Ltd 40256 0600...
Page 183: ...FT 70 Fill Level Inspector Service Manual 7 2 Industrial Dynamics Company Ltd 40256 0600...
Page 225: ...FT 70 Fill Level Inspector Service Manual 9 2 Industrial Dynamics Company Ltd 40256 0600...
Page 233: ...FT 70 Fill Level Inspector Service Manual 10 2 Industrial Dynamics Company Ltd 40256 0600...
Page 243: ...FT 70 Fill Level Inspector Service Manual 10 12 Industrial Dynamics Company Ltd 40256 0600...