Chapter 6: Calibration Procedures
6-31
Calibrating the Bulged End Sensor
Note
Refer to Figure 6-2 when performing this procedure.
1.
Clear the inspection tunnel of any containers so the trigger
beam is not blocked.
2.
Remove the amplifier cover and set the Operation Mode
Selector to Dark (D).
3.
Set the Sensitivity Adjustment to minimum by turning it
counterclockwise until it stops. Notice the gauge needle moves
to reflect setting level and the red Operation Indicator LED is
on.
4.
Slowly turn the Sensitivity Adjustment clockwise until the red
Operation Indicator LED is off. You want the sensitivity
adjustment to be on the edge of when the Operation Indicator
LED turns off. This establishes the minimum sensitivity point.
5.
Verify the setting by using a production container to block the
beam and then remove it. The Operation Indicator should be
off when the container is blocking the beam and on when the
beam is not blocked.
6.
Replace the amplifier cover.
Industrial Dynamics Company, Ltd. ©
Form
40256-0600
Summary of Contents for FT-70c
Page 1: ...FT 70c Service and Technical 40256 0600 Reference Manual for Can Inspection...
Page 14: ...Table of Contents XIII Industrial Dynamics Company Ltd Form 40256 0600...
Page 21: ...FT 70 Fill Level Inspector Service Manual 1 2 Industrial Dynamics Company Ltd 40256 0600...
Page 33: ...FT 70 Fill Level Inspector Service Manual 1 14 Industrial Dynamics Company Ltd 40256 0600...
Page 35: ...FT 70 Fill Level Inspector Service Manual 2 2 Industrial Dynamics Company Ltd 40256 0600...
Page 39: ...FT 70 Fill Level Inspector Service Manual 2 6 Industrial Dynamics Company Ltd 40256 0600...
Page 41: ...FT 70 Fill Level Inspector Service Manual 3 2 Industrial Dynamics Company Ltd 40256 0600...
Page 69: ...FT 70 Fill Level Inspector Service Manual 3 30 Industrial Dynamics Company Ltd 40256 0600...
Page 71: ...FT 70 Fill Level Inspector Service Manual 4 2 Industrial Dynamics Company Ltd 40256 0600...
Page 139: ...FT 70 Fill Level Inspector Service Manual 5 44 Industrial Dynamics Company Ltd 40256 0600...
Page 141: ...FT 70 Fill Level Inspector Service Manual 6 2 Industrial Dynamics Company Ltd 40256 0600...
Page 183: ...FT 70 Fill Level Inspector Service Manual 7 2 Industrial Dynamics Company Ltd 40256 0600...
Page 225: ...FT 70 Fill Level Inspector Service Manual 9 2 Industrial Dynamics Company Ltd 40256 0600...
Page 233: ...FT 70 Fill Level Inspector Service Manual 10 2 Industrial Dynamics Company Ltd 40256 0600...
Page 243: ...FT 70 Fill Level Inspector Service Manual 10 12 Industrial Dynamics Company Ltd 40256 0600...