3-32
Color Calibration
For Port, select the COM port to which the EFI Densitometer 100 is connected.
11.
Measure each color patch using the EFI Densitometer 100.
The Status field of the Mousitometer Measurements dialog box indicates whether the
connection to the EFI Densitometer 100 was successful.
The EFI Densitometer 100 Measurements dialog box also provides a visual map of
your progress.
Begin with Strip A, placing the EFI Densitometer 100 directly on the Measurement
Page and directly over the first color patch. Click the measurement button on the
EFI Densitometer 100 to take a reading. You must click the button the number of
times that you selected for Clicks Per Patch. If you selected multiple clicks per patch, it
is a good idea to move the EFI Densitometer 100 slightly after each measurement
while keeping it within the patch circle.
N
OTE
:
For more accurate measurement, place a plain sheet of paper beneath the
Measurement Page to block underlying colors from being read by the
EFI Densitometer 100.
Continue measuring every color patch on the Measurement Page, being sure not to
skip a single patch.
N
OTE
:
It is critical that you take the measurements in the order outlined in the
EFI Densitometer 100 Measurements dialog box and on the Measurement Page.
12.
When all patches have been measured successfully, click Accept and skip to step 15.