3
3-17
Calibrating with ColorWise Pro Tools and DTP41
spectrophotometer, you can quickly measure color patches generated by the printer
and automatically download these measurements to the Fiery 3850C.
Changing the calibration has the potential to affect all jobs for all users, so you may
want to limit the number of people authorized to perform calibration. You can set an
Administrator password from the Fiery 3850C Control Panel to control access to
calibration.
Multiple users can connect to one Fiery 3850C server with ColorWise Pro Tools, but
only one user at a time can use the Calibrator module. An error message appears if you
try to calibrate when another user is already using ColorWise Pro Tools to calibrate.
N
OTE
:
Before using ColorWise Pro Tools and the DTP41 to calibrate the Fiery 3850C,
follow the instructions on page 3-28 for calibrating the DTP41 spectrophotometer.
T
O
CALIBRATE
THE
F
IERY
3850C
USING
THE
DTP41
1.
Launch ColorWise Pro Tools and connect to the Fiery 3850C.
For instructions on configuring the connection to the Fiery 3850C, see Getting Started.
N
OTE
:
If the connection to the Fiery 3850C from Command WorkStation that also
allows for access to ColorWise Pro Tools is not established, you can directly launch
ColorWise Pro Tools independently of Command WorkStation.
2.
Click Calibrator.