background image

                                             

 

 

 

      GSM1010M System 

          

1000Base-T to 1000Base-SX/LX      

                             Converter 

 

    User and Installation Guide

 

 

Version: 1.0 

 

 

 

 

 

 

 
 
 
 
 

 
 

FibroLAN Ltd. 

Yokneam Star Building, P.O. Box 544, Yokneam-Illit, 20692 ISRAEL 
Tel: 972-4-9591717                                                        Fax: 972-4-9591718  
e-mail: [email protected]                                     web site: www.fibrolan.com 

 

 
 

Summary of Contents for GSM1010M

Page 1: ...1000Base SX LX Converter User and Installation Guide Version 1 0 FibroLAN Ltd Yokneam Star Building P O Box 544 Yokneam Illit 20692 ISRAEL Tel 972 4 9591717 Fax 972 4 9591718 e mail support fibrolan...

Page 2: ...e required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authorit...

Page 3: ...page 42 Warranty Limitation page 44 Thank you for purchasing the GSM1010M GBE Media Converter from FibroLAN We hope that this guide will help you to obtain the best results from the device and minimiz...

Page 4: ...notification mode LST OFF the disconnect of the entire link if one of the F O link is disrupted The Network Device switch or router is notified of the link failure and may provide an alternative path...

Page 5: ...MA enabled GSM1012M 1000Base T RJ 45 to 1000Base LX SC Single Mode 1550nm 40km SNMP managed and MA enabled GSM1013M 1000Base T RJ 45 to 1000Base LX SC Single Mode 1550nm 80km SNMP managed and MA enabl...

Page 6: ...then the DIP switches are functional after powering on the GSM1010M The device is housed in a compact and rugged metal case providing strong free air cooling for extended stable operation and reliabi...

Page 7: ...tom LED steady lit yellow the GSM1010M is connected to a remote MA enabled and active device 4 Port 2 Duplex SC fiber optic connector left Tx right Rx 5 Port 2 LEDs Link steady green lit a F O link ha...

Page 8: ...other active heat generating equipment and avoid placing such devices on the GSM1010M units For wall mount installation Attach the single channel wall mount kit SCH WM part B161 with two supplied scre...

Page 9: ...ch between any line voltage from 100 to 240 VAC 50 60 Hz There is no ON OFF switch on the device When the power is connected to the device the device is ON The POWER LED on the front panel being illum...

Page 10: ...connector may be hazardous to human vision Therefore the following rules must be strictly observed All single mode SM models are CLASS I LASER PRODUCTS And must be handled with special care When not...

Page 11: ...indication for such fault can be seen on the remote device only The FEF implemented in the GSM1010M closes this gap if there is a fault in the incoming receive path of the GSM1010M then the F O Link A...

Page 12: ...mentation Test UP Down Default DIP switches set up S1 S2 in Down position LB disabled S3 S4 in UP position LST ON TP F O Port Setup LB LST S1 S2 S3 S4 TP F O LB loop back In normal operation the LB DI...

Page 13: ...port When this command is set to LST Off a link down at the Fiber port switches off the TP output port thus signaling the attached device upon the failure When the command is set to LST ON a link down...

Page 14: ...propriate signals are transmitted to both remote Network Devices A and B alerting them that a link failure has occurred Figure 2 LST ON operation Test Mode Link Segmentation Test The LST operates in t...

Page 15: ...edded in both the remote units mostly referred to as a CPE and in the access concentrator device deployed in the access node A unique secured in band management protocol allows the two devices communi...

Page 16: ...with options to display the device status to set the channel s description to invoke the LB LST control menu enable disable the channel and to restore the device s default setting and Reboot System Li...

Page 17: ...r at the input port of remote MA device has failed On the other hand if the main F O link is disrupted the LST will take over from SLE and execute the required actions When the LST takes over the FEF...

Page 18: ...al interfaces are available to fit your requirements covering distances 10 20 40 80Km The GSM1010M products are SNMP managed devices The GSM1010M can be monitored and managed from any SNMP management...

Page 19: ...MA enabled and SNMP managed a comprehensive set of monitoring and control functions can be implemented through the Master GSM1010M into GSM1000 MA or GSM1010 MA remote devices The GSM1010M GSM1010 MA...

Page 20: ...r device AND the transmit port to the receive port of the remote device Ensure that the remote connected F O port is setup to 1000Mbps Full Duplex Perform a loop back test to verify link integrity If...

Page 21: ...ware revision levels of all FibroLAN installed equipment 16 Specifications Standard Compliance IEE 802 3 2000 edition 1000Base T 1000Base SX 1000Base LX IEEE802 3z IEEE802 3ab Conversion Method Digita...

Page 22: ...240 VAC 50 60 Hz IEC connector 36 72 VDC PS48 optional Power consumption GSM1010M 7W max Operating temperature 0 45 C 32 113 F Storage temperature 20 80 C 22 F 176 F Humidity 10 90 non condensing Safe...

Page 23: ...e c GSM1010 MA CPE device GSM1010M Management 1 Overview page 24 2 Setting up management page 24 3 Network Connection page 28 4 Configuring the Management Station page 29 5 Managing the GSM1010M page...

Page 24: ...ale connector on the PC Configure the terminal emulation program as follows Baud rate 9600 Parity None Start bits 1 Stop bits 1 Flow control None Start the terminal emulation then power up the device...

Page 25: ...y of this or C ontinue M m For each of the following questions you can press Return to select the value shown in braces or you can enter a new value NETWORK PARAMETERS Do you want a LAN interface Y Th...

Page 26: ...aximum of 4 trap destinations A 0 0 0 0 address is ignored when traps are sent Trap community specify the trap community string for the device max 15 characters System name specify a name that identif...

Page 27: ...this time it is possible to change the management parameters configuration Updating parameter storage Done Applying system configuration Done Login Figure 3 system initialization login Your GSM1010M...

Page 28: ...ld install the MIB file and define the GSM1010M object in the management application see next section The drawing below depicts the GSM1010M functionality Note The remote device can be GSM1010M or GSM...

Page 29: ...hat contains all other MIB files varies between management software packages In your management application add the new MIBs to the already existing list of MIBs and recompile them After MIB installat...

Page 30: ...tree for more detailed status figure 4 In order to monitor the system s status you should open the following branch of the tree private enterprises fibrolan fibrolanSNMP fibrolanMaDevice flCo nvGSM101...

Page 31: ...actions here After the converter and management station are connected and running you will be able to manage your converter through the SNMP manager application Use the management application to view...

Page 32: ...k down Local TP link up Local LX link down Local LX link up Local LX signal lost Local LX signal detect Remote device connected Remote device disconnected Remote power fail Remote TP link down Remote...

Page 33: ...GSM1010M Gigabit Converter 33 Figure 7 traps view...

Page 34: ...the device does not support this feature one of an older revision the display will read Firmware revision n a The status display of TP links may have one of 3 states On Off or Killed Kld in some model...

Page 35: ...yes on Represents a positive selection Equivalent to selecting 1 help Displays the list of available commands ver Displays software version reboot Reboots the SW You will be prompted for confirmation...

Page 36: ...in menu The device status menu This menu contains four options Selecting option 1 would display the system s status figure 9 When choosing option 2 the user would be prompted with a local control menu...

Page 37: ...onfirmation code 26974 Figure 6 displays the menu as it appears on the terminal Device control 1 System status 2 Set FO port Loopback mode 3 Set TP port Loopback mode 4 Set FO TP port LST mode 5 Set T...

Page 38: ...may result in upgrade failure Simply let the process be as automated as possible Software control 1 View S W upgrade parameters 2 Change TFTP server address 3 Select upgrade S W version name 4 Select...

Page 39: ...take some time to complete and the progress is indicated via a dot based progress bar Failure during any of the stages will result in an error message being displayed after which normal execution of t...

Page 40: ...or to enter the device s control menu 2 GSM1010M MA link remote device GSM1000 MA 1 Device status 2 Device control 0 Back to GSM1010M MA menu Figure 1 GSM1000 MA main menu CPE status The CPE s status...

Page 41: ...th the loop back test that is found in other devices Back to main module menu implies back to main device menu Channel LB LST control 1 P2 P1 LST mode 2 P2 loop back mode 0 Back to device control menu...

Page 42: ...ure 1 GSM1010 MA main menu CPE status The CPE s status figure 2 contains the following information Link status FO port and TP port Signal detect status FO port Device enabled LST mode Loop back LB mod...

Page 43: ...device main menu Device LB LST control 1 FO TP LST mode 2 FO loop back mode 0 Back to device control menu Figure 4 GSM1010 MA LB LST control menu Selecting any of the options will prompt the user for...

Page 44: ...ly from the reseller from which you have purchased the device however you may refer directly to FibroLAN Ltd to claim the warranty providing reasonable proof that the reseller ceased operation and or...