17.2
Technical data, electrical
17.2.1
Power supply
Type
EMCS-ST-42-...
EMCS-ST-57-...
Load voltage supply
Nominal voltage
[V DC]
24
Voltage range
[V DC]
24
±
15 %
Nominal current at 24 V
[A]
3.0
5.3
Protective functions
–
Protection against polarity reversal
–
Overcurrent protection
(Fuse 10 A, not resettable)
Logic voltage supply (DIO and IO-Link operation)
Nominal voltage
[V DC]
24
Voltage range
[V DC]
24
±
15 %
Logic current consumption
(Logic, Pin 1) loaded with rotary
encoder and display compon-
ents
–
DIO operation
[mA]
100 ... 300
–
IO-Link operation
[mA]
100 ... 150
Protective functions
–
Protection against polarity reversal
–
Overcurrent protection
(Fuse 2 A, not resettable)
Tab. 43 Technical data: power supply