7
Transport and storage
Transport and storage conditions
–
Store and transport the product in its original packaging.
–
Store product in a cool, dry, shaded and corrosion protected environment.
–
Store product in ambient conditions without oils, greases and degreasing vapours.
–
Ensure short storage times.
8
Assembly
8.1
Safety
WARNING!
Risk of injury due to unexpected movement of components.
The drive can move freely in the voltage-free state. This can cause unexpected movements of the con-
nected mechanics and crush parts of the body.
•
Bring moving parts of the mechanical system into a safe position.
8.2
Mounting distances
Drive systems with integrated drive EMCS-ST can be connected in series. When connecting drive sys-
tems in series, a minimum distance must be maintained to allow the heat generated during operation
to dissipate by allowing sufficient air flow.
•
Maintain a minimum lateral distance of at least 20 mm between the integrated drive EMCS-ST and
adjacent components.
Assembly instructions
–
Mount the drive system flat on a sufficiently stable mounting surface.
–
Maintain minimum distances and installation space to guarantee sufficient air flow. The ambient
air must be able to flow unhindered around the integrated drive EMCS-ST.
–
Take into account the clearance required for connecting the cables (the cables at the [Logic] and
[Power] connections can be routed upwards (straight) or laterally (angled)).
–
Do not install any temperature-sensitive components near the integrated drive EMCS-ST. The
integrated drive EMCS-ST can become very hot during operation.
8.3
Installation
•
Mount the product
è
Instruction manual, mounting the corresponding drive.
Transport and storage
15
Festo — EMCS-ST — 2020-04a
Summary of Contents for EMCS-ST
Page 1: ...8123666 EMCS ST Integrated drive 8123666 2020 04a 8123668 Operating instructions ...
Page 29: ...11 1 2 Dimension reference system Drive system 29 Festo EMCS ST 2020 04a ...
Page 48: ...Fig 22 Single end to end operation Drive system 48 Festo EMCS ST 2020 04a ...
Page 50: ...Fig 23 Stop and continue single end to end motion Drive system 50 Festo EMCS ST 2020 04a ...
Page 54: ...Fig 25 End to end operation with press function Drive system 54 Festo EMCS ST 2020 04a ...