![Festo EMCS-ST Operating Instructions Manual Download Page 49](http://html.mh-extra.com/html/festo/emcs-st/emcs-st_operating-instructions-manual_2283346049.webp)
Timing: stop and continue single end-to-end run (example motion "Mov
Out
")
The diagram shows the stopping and continuing of the "Mov
Out
" motions from the "Stop
Out
" com-
mand to reaching the "Lim
Out
" end position with the status data in DIO and IO-Link operation.
Stop task Stop
Out
–
Activation of the stop task DIO: digital input DI1 "Mov
In
" = 0 and DI2 "Mov
Out
" = 0
–
Activation of the stop task IO-Link: parameter 0x0029.1 = false and 0x0029.2 = false or
system parameter0x0002 (value 0xCA "Stop motion")
Motion task Start
Out
–
Activation of the motion task DIO: digital input DI2 "Mov
Out
" = 1 and DI1 "Mov
In
" = 0
–
Activation of the motion task IO-Link: parameter 0x0029.2 = true and 0x0029.1 = false or
system parameter 0x0002 (value 0xC9 "Move Out")
Drive system
49
Festo — EMCS-ST — 2020-04a
Summary of Contents for EMCS-ST
Page 1: ...8123666 EMCS ST Integrated drive 8123666 2020 04a 8123668 Operating instructions ...
Page 29: ...11 1 2 Dimension reference system Drive system 29 Festo EMCS ST 2020 04a ...
Page 48: ...Fig 22 Single end to end operation Drive system 48 Festo EMCS ST 2020 04a ...
Page 50: ...Fig 23 Stop and continue single end to end motion Drive system 50 Festo EMCS ST 2020 04a ...
Page 54: ...Fig 25 End to end operation with press function Drive system 54 Festo EMCS ST 2020 04a ...