Index.
Subindex
Name
Description
Data type
(length)
User access
1)
U = User
M = Maintenance
personnel
S = Specialist
U
W
S
0x0029.2
(41.2)
Move "Out"
Control command for executing
the motion "Mov
Out
" to the
"Lim
Out
" end position.
–
This signal works in conjunc-
tion with Move "In"
è
–
Corresponds to the function
of digital input 2 (DI2).
BooleanT
(1 bit)
R/W R/W R/W
0x0029.3
(41.3)
Quit Error
Control command for acknow-
ledging errors
–
true: start error acknow-
ledgement
–
false: do not start error
acknowledgement
BooleanT
(1 bit)
R/W R/W R/W
1) R/W = read and write, R = read only, W = write only
Tab. 35 Process data
Bit
ProcessDataInput
15
...
4
3
2
1
0
Control data
State
"Device"
State
"Move"
State "Out"
State "In"
Index.Subindex
–
0x0028.4
(40.4)
0x0028.3
(40.3)
0x0028.2
(40.2)
0x0028.1
(40.1)
Tab. 36 ProcessDataInput telegram structure
Bit
ProcessDataOut-
put
15
...
3
2
1
0
Status data
Quit Error
Move "Out"
Move "In"
Index.Subindex
–
0x0029.3
(41.3)
0x0029.2
(41.2)
0x0029.1
(41.1)
Tab. 37 ProcessDataOutput telegram structure
IO-Link
74
Festo — EMCS-ST — 2020-04a
Summary of Contents for EMCS-ST
Page 1: ...8123666 EMCS ST Integrated drive 8123666 2020 04a 8123668 Operating instructions ...
Page 29: ...11 1 2 Dimension reference system Drive system 29 Festo EMCS ST 2020 04a ...
Page 48: ...Fig 22 Single end to end operation Drive system 48 Festo EMCS ST 2020 04a ...
Page 50: ...Fig 23 Stop and continue single end to end motion Drive system 50 Festo EMCS ST 2020 04a ...
Page 54: ...Fig 25 End to end operation with press function Drive system 54 Festo EMCS ST 2020 04a ...