5
Commissioning
54
Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English
5.5
I/O interface
5.5.1
Profiles for selection
Two profiles are available for control of the CMMO-ST via the I/O interface:
Valve profile (7)
The valve profile is based on the control of pneumatic valves and is very easy to configure. Use this
profile if
7 position records
are sufficient (simple positioning operation only).
Binary profile (31)
The binary profile uses 5 binary coded inputs and can therefore select
31 records
(plus record 0 =
homing).
The following are also available:
–
jogging and teaching
–
Force mode
–
Speed mode
–
Record Linking
Initial start-up
During the initial start-up phase the valve profile is active. An initial start-up is thereby possible with
both a web browser and with FCT.
Change profile
A change between profiles must be effected using FCT. FCT ensures that no inconsistent states arise
when switching.
The web server only supports the valve profile. A change to the binary profile is not possible.