4
Electrical installation
Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English
33
Observe the tightening torques specified in the documentation for the cables and plugs
used. The assortment of plugs supplied with the CMMO-ST is also available under the
type code NEKM-C-10.
4.2
Power supply [X9]
Port
Pin
Function
X9
5
1
5
1
1
–
Do not connect!
2
–
Do not connect!
3
Logic voltage
+24 V supply of the control
electronics
4
Reference
potential
0 V reference potential for load
voltage, logic voltage, STO and
controller interface
5
Load voltage
+24 V supply of the power
output stage and the motor
Tab. 4.2
Port X9 “Power” (power supply)
Caution
Damage to the device
With port X9, always pay attention to the correct pin number corresponding to the plug
location on the device.
•
Make sure that Pin 1 and Pin 2 are
not