![Festo CMMO-ST Manual Download Page 61](http://html1.mh-extra.com/html/festo/cmmo-st/cmmo-st_manual_2283099061.webp)
5
Commissioning
Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English
61
Requirements
Drive is referenced and ready.
Start record 1
Record 1 is started by setting input Pos1.
Terminate record 1
Record 1 is terminated if input Pos1 is removed. The output OnPos1 is not set in this example, as the
target position has not yet been reached.
Start record 2
Record 2 is started by setting input Pos2.
Destination 2 reached
After reaching the parameterised target position window and after expiration of the parameterised
damping time, the output OnPos2 is set.