Commissioning
Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English
47
1. Switch to the parameterisation page by clicking <Parameters> at the far right.
2. Enter the type code of your EPCO drive in the uppermost text box in accordance with the rating
plate, and click <Search> to download a suitable parameter file from the Festo website (Internet
access required).
Caution
: Incomplete entry of the code may result in malfunctions, uncontrolled
behaviour and damage.
If you do not have a second network connection (e.g. WLAN/WiFi), you can continue to step 4 and
use the parameter file on the CD.
Fig. 5.3
Website: parameters
3. Click <Save> in the Windows dialogue window “Download file” to save the file to your computer.
4. Click <Browse> and select the downloaded parameter file in the dialogue window.
Fig. 5.4
Selecting a parameter file
5. Click the box next to “Device Control” to assume higher-order control.
Fig. 5.5
Assuming higher-order control
6. Click on <Download parameter set to CMMO>.
Fig. 5.6
Transferring a parameter file to the CMMO-ST