![Festo CMMO-ST Manual Download Page 102](http://html1.mh-extra.com/html/festo/cmmo-st/cmmo-st_manual_2283099102.webp)
6
Diagnostics
102
Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English
Table of error messages
44h
Parameter file is not suitable for the firmware
Can be parameterised as: -/
W
/I
Diagnostic memory: always
The parameter file that was just written to the controller is not suitable for the firmware of the device.
As much data as possible is automatically taken over from the parameter file. Parameters that are
not initialised through the parameter file are imported from the default parameter file. If new firm-
ware software is required, not all parameters may have to be written.
•
Enter a valid parameter set in the device.
–
For parameterisation as a warning: The warning disappears if a new parameter file is successfully
written.
Tab. 6.3
Table of error messages