5
Commissioning
62
Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English
3) Valve profile: Record switching
0
t
Vel
t
Pos1
t
Pos2
t
REF
t
ENABLE
t
RESET
t
Ready
t
Referenced
t
OnPos1
t
OnPos2
1
2
3
1
Start record 1
2
Switching
3
Destination 2 reached
Fig. 5.18 Timing diagram: Valve profile – record switching