53
!
"
#
"
!
#
$
%
&
Planer-Thicknesser
A 941 / AD 941 / AD 951
1.
Switch the machine off and ensure that it cannot be
switched on again.
2.
Remove the cover lid.
3.
Lubricate the drive chain with machine grease.
Slowly turn the chain in a clockwise direction using
a socket spanner.
4.
Mount the cover plate on again.
!
Cover plate
"
Drive chain
#
Socket spanner
10.4.1 Lubricating the drive chain feed rollers
Fig. 10-1: Drive chain
10.4.2 Thicknesser table height spindles and chain drive
Fig. 10-2: Lubricating the chain
Fig. 10-3: Tension the drive chain
Depending on the quantity of work, dust and chips have
to be cleaned off the space under the thicknesser table
periodically.
1.
Position the thicknesser table in the top most position
(see thicknesser table height adjustment).
2.
Disconnect the machine from the mains power supply
3.
Loosen the screws. Remove the cover.
4.
Remove dust and chips carefully. Clean height guide
and height spindle
5.
Greasing the height spindle (thicknesser planing table)
Only high quality machine grease order nr. 10.2.001
may be used! (Shell Retinax LX2)
Interval Every 40 operating hours, at least twice every
month or in the event of sluggish action.
6.
Clean the entire length of the drive chain and
relubricate with machine grease
7.
Check chain tension and retighten if necessary.
(Screws
5
, Clamping screw
6
)
Interval: Twice a year
8.
Slide the cover plate in place and secure with screws
Move the thicknesser table fully upwards.
!
Screws
"
Cover plate
#
Spindles
$
Chain
%
Screws
&
Clamping screw
Service
10.4 Maintenance work
Summary of Contents for AD 941