![Fayat Bomag BW 900-50 Service Manual Download Page 65](http://html1.mh-extra.com/html/fayat/bomag-bw-900-50/bomag-bw-900-50_service-manual_546858065.webp)
n
For measuring current the individual conductor must be fully
enclosed by the measuring tongs, the actual measurement
takes place without contact.
The magnet tester is used to test solenoid valves and magnetic
coils.
The test lamp responds to the magnetic fields of A.C-voltage, D.C.-
voltage and permanent magnets.
n
The component to be tested does not need to be removed.
n
The magnetic coil can also be tested under a protective cap.
The electric power of a module within a circuit can be indirectly
determined (calculated) by separate measuring of current and
voltage.
However, there are also pure power meters with 4 connections
available. The power meter has a electro-dynamic measuring
mechanism. The current circuit must be opened for measuring.
Take care when performing power measurements: Voltage or cur-
rent path may already be overloaded during the measurement,
even though the end stop in the meter has not yet been reached.
Fig. 46
Magnet tester
Fig. 47: Magnet tester
Power measurement
Fig. 48
Electric systems – Basic principles
BW 900-50
68
Go
to
Discount-Equipment.com
to
order
your
parts