5.
NOTICE!
Run the following pressure test for max. 3
seconds.
Move the travel lever quickly to both travel directions
Fig. 116 and read the high pressure gauges.
ð
Nominal value
approx. 320 bar
Evaluation of measurement
If the nominal value is reached in one
travel direction only, check the high pres-
sure limiting valves.
If the nominal value is not reached in
both directions, check the travel pump;
replace if necessary.
5.5.5 Pressure tests in the vibration circuit
Special tools
Hydraulic test case
NOTICE!
Perform measurements at operating temperature
of the hydraulic oil (40 °C).
1.
Drive the drum of the machine onto an elastic base (rubber
buffers)
Fig. 117 and block the rear drum additionally with
suitable chocks.
Fig. 116
Fig. 117
Hydraulic system – Tests and adjustments
BW 900-50
127
Go
to
Discount-Equipment.com
to
order
your
parts