6
Charge oil filter with pressure test port
7
Rear drum drive motor
8
Front drum drive motor
9
Steering / charge / vibration pump
M Pressure test ports
Hydrostatic braking
During travel operation the machine is braked by the closed
hydraulic circuit. When moving the travel lever to neutral position
the supply from the pump is interrupted, the machine is hydrostati-
cally braked.
5.4.2 Vibration circuit
The vibration circuit is an open hydraulic circuit.
Brake
Hydraulic system – Description of hydraulic circuits
BW 900-50