Rate Meter Setup | Solids (Generic Wizard)
RATE METER SETUP | SOLIDS (GENERIC WIZARD)
The Jackal can be configured to monitor solid products. If only one input
is used the main screen will display the flow information in kg, lb, kg/s,
kg/hr, T/hr, lb/s. If using the speed & area function the Jackal can also display
kg/Ha, bu/ac, T/Ha.
Refer to (
) for Rate Monitor setup to display kg/Ha
Sensors Required
x
Shaft sensor kit (2076 Slow /2077 Fast) (2 wire) or
x
Proximity sensor kit (2010P) (3 wire)
Available Connections (
This setup section assumes that physical wiring for the required sensors have been
completed.
If not please refer to
SETUP
1.
Ensure there is product in bin/tank
2.
Have a bucket ready to catch the product
3.
Have a set of scales (e.g. Farmscan Ag Part # 2199) ready to weigh the product
From the front screen press
SETUP
Highlight
WIZARD
& press
SELECT
Highlight
GENERIC WIZARD
& press
NEXT
Highlight the
INPUT
number
X: the sensor wire is
connected into on the rear
of the Jackal & press
NEXT
Enable the input by pressing
EDIT
Choose your unit of pulse.
pulse/kg
or
pulse/lb
Highlight TARGET & press
EDIT
Using the NAV buttons enter
the target amount (kg) to be
measured. i.e. 10.0000
Press EXIT when done.