![FARMSCAN Jackal v2 General Description Manual Download Page 5](http://html.mh-extra.com/html/farmscan/jackal-v2/jackal-v2_general-description-manual_545383005.webp)
September 2015
www.farmscanag.com
AM-JACKAL-3
4
Connections
CONNECTIONS
The connector on the rear of the Jackal has the following connection points available for use.
AVAILABLE CONNECTIONS
A
TOP ROW (GREY PLUG)
B
BOTTOM ROW (GREEN PLUG)
A1 GND
(Ground/Earth/0V)
B1 IN1
(1x Coil Input
ONLY
/Prox/Flow
–
Square Wave)
–
Hz
A2 IN13
High/Low | On/Off
Full/Empty
–
I/O
B2 IN2
(Prox/Reed/Switch/Alarm)
–
Hz
A3 IN12
High/Low | On/Off
Full/Empty
–
I/O
B3 IN3
(Prox/Reed/Switch/Alarm)
–
Hz
A4 IN11
High/Low | On/Off
Full/Empty
–
I/O
B4 IN4
(Prox/Reed/Switch/Alarm)
–
Hz
A5 IN10
High/Low | On/Off
Full/Empty
–
I/O
B5 IN5
(Prox/Reed/Switch/Alarm)
–
Hz
A6 IN9
High/Low | On/Off
Full/Empty
–
I/O
B6 IN6
(Prox/Reed/Switch/Alarm)
–
Hz
A7 IN8
(Varying volt sensor)
–
0-5V
B7 IN7
(Varying volt sensor)
–
0-5V
A8 Not Used
B8 Out1
(solenoid/shutoff/pulse/radar output )
Pulls to GND ^
A9 Not Used
B9 Out2
(+12V Supply Out)
–
Sensor/GPS Power ^^
A10 RS232 Tx (Transmit)
B10 BATT
+VE
(+12V Battery Terminal)
A11 RS232 Rx (Receive)
–
GPS Input
B11 BATT -VE
(0V/GND Battery Terminal, Vehicle Ground)
x
^ B8/OUT1 is Open Circuit when the output is NOT ACTIVE, and is connected to GND when the
output is active
x
^^ B9/OUT2 will only power the sensors when the unit is turned on
x
Any Inputs 1-13 can be used as remote/run hold