![FARMSCAN Jackal v2 General Description Manual Download Page 35](http://html.mh-extra.com/html/farmscan/jackal-v2/jackal-v2_general-description-manual_545383035.webp)
September 2015
www.farmscanag.com
AM-JACKAL-3
34
Air/Volt/Depth/%/Temp Pressure Sensor
AIR/VOLT/DEPTH/%/TEMP PRESSURE SENSOR
The Jackal can be configured to read & display a pressure sensor, voltage,
percentage, temperature and display:
kPa, psi, bar, Volt, %,
˚
C
Sensors Required:
x
AA-119H or AA-119L (pressure)
x
Any other style that outputs a voltage. i.e. Position sensor (AA-430)
for displaying depth as a percentage (%)
Available Connections (
This setup section assumes that physical wiring for the required sensors have been completed.
If not please refer to
CALIBRATION (MANUAL)
The example below details setting up
a LIQUID PRESSURE SENSOR
.
From the front screen press
SETUP
Highlight
WIZARD
& press
SELECT
Highlight
GENERIC WIZARD
&
press
SELECT
Highlight the
INPUT
number
(7-8)
to where the sensor
wire is connected into on the
rear of the Jackal & press
NEXT
.
Enable the input by pressing
EDIT
Press
EDIT
to change the
unit. kPa,psi,bar,Volt,%,
˚
C.
i.e. kPa
Highlight the 1
st
CAL HIGH
value and
EDIT
the field to
set the maximum the device
will be able to display. I.e.
600kPa. Current input
voltage of input is displayed
in the top left corner.
Using the manufactures
guide set the maximum
voltage of the sensor.
e.g. 5.000v by pressing
EDIT
NB : If manufacture values
are not available, please
instructions