September 2015
www.farmscanag.com
AM-JACKAL-3
26
Flow Meter Setup (Wizard)
CALIBRATION (MANUAL SET)
Manual set allows for the manual input of a known pulse per pitre (PPL) factor. The pulse per litre factor can be
obtained from the flow meter manufacture or from the plastic tag attached to the flowmeter.
Highlight 1.000000 under
MANUAL RATIO & press EDIT
Using the NAV buttons enter
the PPL factor as displayed on
the flow meter tag.
i.e. 91.2
Press EXIT when done.
Press NEXT to accept the new
manual ratio (PPL)
Using the NAV buttons
select how you would like
the UOD to be displayed on
the front screen.
Press NEXT
You have the option to set
Alarm Min/Max points if
required. Using the NAV
buttons select & EDIT as
required. Press NEXT
Name the input if you desire,
Press EDIT
or Press NEXT
The Wizard is now complete.
Press NEXT
You will be returned to the
Setup Screen.
Press EXIT
Example: 1 UP monitoring
Flow Meter in L/Min
THIS ENDS THE MANUAL CALIBRATION WIZARD SETUP FOR FLOW METER
** IT IS ADVISED TO CHECK YOUR MANUAL CALIBRATION BY MEASURING OUT A KNOWN QTY TO CONFIRM PPL** THIS
CAN BE DONE BY COMPLETING THE CALIBRATION AUTO SET ON THE
Summary of Contents for Jackal v2
Page 1: ......