![FARMSCAN Jackal v2 General Description Manual Download Page 41](http://html.mh-extra.com/html/farmscan/jackal-v2/jackal-v2_general-description-manual_545383041.webp)
September 2015
www.farmscanag.com
AM-JACKAL-3
40
Inputs (Manual Setup)
INPUTS (MANUAL SETUP)
The Jackal has 13 available & selectable inputs. Refer to the sensor overview tables from
FRONT SCREEN > SETUP > INPUTS
meter / pulse (m)
B1-B6
feet / pulse (ft)
B1-B6
yard / pulse (yd)
B1-B6
Inch / pulse (in)
B1-B6
kilometer / pulse (km)
B1-B6
mile / pulse (mi)
B1-B6
pulse / Kilogram (kg)
B1-B6
pulse / US pound (lb)
B1-B6
pulse / litre (l)
B1-B6
pulse / US gallon (gal)
B1-B6
pulse / Bushel (bu)
B1-B6
pulse / rev (rpm)
B1-B6
pulse / bale (bale)
B1-B6
pulse / unit (unit)
B1-B6
pulse / each (each)
B1-B6
kPa / psi / bar / Volt
/ % / Temp
˚
C
B7 & A7
High/Low, On/Off,
Full/Empty
A2 & A6
13 Inputs are available on the Jackal
Refer to
for input usage
After selecting your input pressing the
EDIT
button allows
you to enable/disable the port
CALIBRATION METHOD
–
TARGET & MANUAL RATIO
When the input has been enabled, using the
NAV buttons
navigates you through the calibration setup.
Here you can also select your calibration method.
N.B. Different inputs have different calibration methods.
Review the wizard setups for example calibration methods
TARGET
allows you to use the auto calibrate function and enter a known Unit Of Measure to calibrate pulses to. When the
known UOM is entered the start button can be used to count the necessary pulses.
Once the pulse have been counted press the
CALC
to auto update the
MANUAL RATIO
field.
MANUAL RATIO
allows you to enter a known calibration factor. This could be a pulse per litre factor for a flow meter, a
known wheel circumference for speed & area (pulse/m), or number of magnets for rpm.
Summary of Contents for Jackal v2