10
2.4
PRE-COMMISSIONING CHECK
2.4.1
Clean out pan thoroughly using hot water and detergent. Rinse out and dry thoroughly.
Note
- For further detail with regard to cleaning, refer to Section 8.
2.4.2 Checking Controller Operation
To check operation of controls, refer to Using the Controller - Section 6.2.3.
2.4.3 Checking Oil Filtration Pump E3840F & E3840FX only.
To check operation of oil filtration pump, refer to Section 7.
2.5
TEMPERATURE LIMIT THERMOSTAT
The unit is equipped with an additional temperature limit thermostat, independent of the main
controller. In the case of operating thermostat failure, allowing oil temperature to rise above
predetermined legislation safe zone (230⁰C), limit device will activate and cut power to
controller and elements.
To re-set temperature limit thermostat: (Refer to Figure 5)
a) Switch fryer ON/OFF switch to OFF position.
b) Allow oil to cool below
150⁰C
c) To reset limit thermostat, unscrew black dust cap located at element box rear. Press reset
button and replace cap.
d) Turn fryer ON/OFF switch to ON position and press start button.
e) Reselect temperature.
f) If limit thermostat reactivates carry out fault finding on temperature control circuitry.
2.6
OIL LEVEL SENSOR (E3840X & E3840FX only)
The unit is equipped with an additional Oil Level Sensor (Patent No.
GB2584184
).
When the oil level drops to at least 15mm below the MIN mark, then the Top Up Oil LED will
indicate (Orange oil can symbol) warning the user that the oil level has dropped considerably.
When the oil level drops below at least 45mm below the MIN mark, the Low Oil Level LED will
indicate (Flashing red hazard triangle) warning the user that the oil level is unacceptable.
At this point the fryer will stop the elements from energising. The fryer cannot be started until the
fry pot has been filled with oil to an acceptable level.
2.7
INSTRUCTION TO INSTALLER
After installing and commissioning appliance, please hand Instructions to user or purchaser
and ensure that the person(s) responsible understands the instructions and how to
correctly operate and clean the unit in a safe manner.
Emphasis should be given to safe operation and use of drain valve and oil bucket. Oil bucket
should not be overfilled to allow safe movement. Oil should be allowed to cool before any
manual handling.
Summary of Contents for E3840
Page 20: ...16 5 0 CRITICAL DIMENSIONS Figure 7 Critical dimensions...
Page 30: ...11 0 WIRING DIAGRAMS 11 1 E3840 Wiring diagram 25...
Page 31: ...26 11 2 E3840 Circuit diagram...
Page 32: ...27 11 3 E3840X Wiring diagram...
Page 33: ...27 11 4 E3840X Circuit diagram...
Page 34: ...27 11 5 E3840F Wiring diagram...
Page 35: ...27 11 6 E3840F Circuit diagram...
Page 36: ...27 11 7 E3840FX Wiring diagram...