9
2.3.3 Additional Controls
Figure 4 - Additional Controls
The following additional controls are located behind cabinet door.
1. Fryer ON/OFF Switch
Cuts power to appliance.
2. Check Oil Level Lamp / Buzzer
Fryer has a ‘check oil level’ indicator to prompt operator to check there is oil / sufficient oil in the
pan.
3. Start Button
Fryer has a start button. Once operator has established there is sufficient oil in the pan, pushing
will engage the controller (See fig 2 or 3).
4. Filtration Switch (E3840F & E3840FX Models Only)
Used to operate filtration pump when filtering is required.
2.3.4 Temperature Safety Limit Device Reset Button
Located on rear of element box, below black dust cap, refer to Figure 5.
Figure 5
– Reset Button
2.3.5 E3840 Controller Diagnostic Indicators (Refer to Wiring Diagrams)
On PCB Controller
CR2,Green LED
‘ON’ indicates heat demand. CR 2 , Green LED ‘OFF’ indicates no heat
demand. CR9,Red LED flashes if temperature probe is either short or open circuited.
CR9,Red LED is permanently ‘ON’ to indicate system is OK. Set point is +/-7⁰C of mid-set point.