background image

Innova 40i P / 40i P-B

Installation / Operation Manual

Manual code: 14460120

Manual ver sion: 1503

Software ver sion: 2.3x

Summary of Contents for DRO Innova 40i P-B

Page 1: ...Innova 40i P 40i P B Installation Operation Manual Manual code 14460120 Manual version 1503 Software version 2 3x...

Page 2: ...Tools and references 7 2 4 1 Tools 7 2 4 1 1 Tool change 7 2 4 1 2 Set a new tool in the table 7 2 4 1 3 Tool compensation 8 2 4 2 Reference 8 2 4 2 1 Changing the reference 9 2 4 2 2 Setting part zer...

Page 3: ...eters 22 3 6 2 User parameters 22 3 6 2 1 Language 22 3 6 2 2 Screen color 23 3 6 3 Installer parameters 23 3 6 3 1 Parameter backup into USB memory 23 3 6 3 2 DRO 23 3 6 3 3 Feedback 25 3 6 3 4 Compe...

Page 4: ...en applying voltage or after pressing the on off key On power up an initial screen comes up for a few seconds and then the work screen is displayed Turns the DRO on or off Keys for entering numeric va...

Page 5: ...ns Active reference Nr Active tool Nr Display units mm inch Display mode INC ABS Set Clear Chronometer DISPLAY AREA STATUS BAR FUNCTION BAR Probe ON Home search Setup Setup CHANGE Reference Part datum...

Page 6: ...on and drill the hole Move the axis until the display reads 37 000 C position and drill the hole Move the axis until the display reads 62 000 D position and drill the hole 2 1 2 2 Incremental mode The...

Page 7: ...et on the display or zero it Clear 2 2 1 In Set mode indicated with an S on the upper status bar To preset a value for an axis To zero the axis either preset a 0 value using the previous keystroke seq...

Page 8: ...play will show the position value preset in parameter user offset see Reference This icon indicates that the axis must be homed Note When all the required axes are homed the DRO automatically leaves t...

Page 9: ...ed in two axes at the same time Tool compensation on off for this corner of the pocket Tool compensation on off for this corner of the pocket Tool compensation on off for this corner of the pocket Too...

Page 10: ...the tool being used Z axis Activate Z axis homing Optional Activate the probe mode if the probe has been configured and it is being used Select the Z axis to set the datum point on the vertical axis S...

Page 11: ...to zero 2 4 2 4 Search for the center of a part Set or change the tool It activates the probe mode If the probe has been set it may be used to touch the desired sides of the part Move the tool to the...

Page 12: ...shows the data of the selected cycle so it can be identified easily Deletes the selected cycle To edit the values of the selected cycle Execute run the cycle The cycles that may be programmed are Bolt...

Page 13: ...ithout having to calculate the coordinates X Y of each hole by simply keying in some basic data Select plane X Y Position of the first hole Distance between holes Number of holes Alpha Inclination of...

Page 14: ...t coordinates he simply has to move the axes to zero When presetting a value on an axis press ENTER to go on to the next axis and validate the data just entered 2 5 2 Programs Various cycles may be jo...

Page 15: ...result or Insert a value into the calculator Exit the calculator Set one of the axis with the result of the calculator To do this access the calculator by pressing the Calc button of the function bar...

Page 16: ...ar indicates the number of the current hole and the total number of holes programmed in the cycle Once positioned at the drilling point touch the surface with the tool Press the Z axis key The Z axis...

Page 17: ...s respectively For example 100 000 132 035 0 435 124 500 133 005 132 035 0 435 140 005 870 020 132 435 0 435 145 755 133 870 132 035 0 435 140 500 191 890 205 545 10 540 40 500 2 5 5 1 Turn the probe...

Page 18: ...on to the support arm using two set screws 3 2 Mounting of the built in model The DRO is ready to be built into an operator panel or pendant The name of this model is special a B has been added at th...

Page 19: ...pment rated minimum 300 V AC The cord type shall be SO SJO or STO Suitable Strain Relief means must be provided in the cord set to assure the connection of the plug and the fitting WARNING Do not hand...

Page 20: ...soidal signal It admits SSI communication for absolute encoders Maximum frequency 250 KHz minimum gap between flanks 950 nsec Phase shift 90 20 hysteresis 0 25 V Vmax 7V maximum input current 3mA High...

Page 21: ...0 mA Vin 24 V High threshold logic state 1 VIH From 12 5 V DC on Low threshold logic state 0 VIL Below 4 V DC Maximum nominal voltage Vimax 35 V DC The unit has two probe inputs 5 V DC and 24 V DC at...

Page 22: ...nnection Always mount it vertically so its keyboard is within operator s reach and its digits are easily visible at operator s eye level Do not connect or disconnect the DRO connectors while it is und...

Page 23: ...encoder or when doing a repair They are parameters related to the machine feedback and to the DRO itself 3 TEST MODE To check the various status of different elements of the DRO such as screen keyboar...

Page 24: ...231202 3 6 3 1 Parameter backup into USB memory If a USB memory is connected it is possible to save and recover DRO parameters Multi point compensdation tables User programs 3 6 3 2 DRO It configures...

Page 25: ...hows a window indicating the feed rate of each axis The units will be m min or inches min depending on whether MM or INCH is active 5 Hide axis Hides the axis and does not display its value The names...

Page 26: ...he linear encoder 1 2 ROTARY It requests the number of pulses turn of the encoder and the number of turns the encoder must make for the machine to consider a 360 movement mechanical gear ratio For SSI...

Page 27: ...ollowing parameters Resolution Only requested if the axis is linear The resolution to be used with FAGOR absolute linear encoders is 0 0001 mm Number of bits It sets the digital communication between...

Page 28: ...it to enter the compensation value The following window is opened Even when working in inches this value must always be in mm Enter the linear compensation value and press Enter 3 MULTI POINT Choose M...

Page 29: ...It may be used to know system information such as software version hardware version software burning date etc Pressing the Test key displays the software and hardware versions software recording date...

Page 30: ...g regulations 4 2 1 1 Electromagnetic compatibility EN 61000 6 2 2005 Standard on immunity in industrial environments EN 61000 6 4 2007 Standard on emission in industrial environments According to the...

Page 31: ...ronment This unit is ready to be used in Industrial Environments complying with the directives and regulations effective in the European Community Install this DRO vertically so its power switch of th...

Page 32: ...ct was launched up to 8 years after such product has disappeared from the product catalog It is entirely up to FAGOR to determine whether a repair is to be considered under warranty EXCLUDING CLAUSES...

Page 33: ...ternal circuits of the equipment especially in high humidity conditions To clean the equipment nonabrasive dish washing detergents are recommended in liquid never powder form or 75 isotropic alcohol w...

Reviews: