CNC8070
R
EF
. 0402
E
RROR
SOLUTIONS
Page 53 of 128
Errors 1000-1999
1484
'Signal number out of range'
DETECTION
During execution.
CAUSE
The signal number programmed in the instruction #WAIT, #MEET or #SIGNAL is
wrong.
SOLUTION
The signal programmed in the instructions #WAIT, #MEET and #SIGNAL must be
between 1 and 10.
1485
'#WAIT/#MEET not effective'
DETECTION
During execution.
CAUSE
It informs the user that the instruction #WAIT or #MEET does not generate any wait
because the delayed activation of a signal in the same channel has been programmed
in it.
SOLUTION
Check the program.
1486
'Program: #SIGNAL [signal, signal, signal, ...]'
DETECTION
During execution.
CAUSE
The possible causes are:
• The syntax of the instruction is wrong.
• Only the block number of a label may be programmed in the same block as the
instruction.
SOLUTION
In the first case, refer to the programming manual. In the second case, program in
different blocks.
1487
'Program: #CLEAR [signal, signal, signal, ...]'
DETECTION
During execution.
CAUSE
The possible causes are:
• The syntax of the instruction is wrong.
• Only the block number of a label may be programmed in the same block as the
instruction.
SOLUTION
In the first case, refer to the programming manual. In the second case, program in
different blocks.
1489
'Axis name repeated in the resulting group'
DETECTION
During execution.
CAUSE
Using the instruction #RENAME AX, more than one axis have been renamed with
the same name.
SOLUTION
Rename each axis with a different name so the resulting group of axes in the channel
does not have two with the same name.
1490
'G63 requires programming M19 before'
DETECTION
During execution.
CAUSE
An attempt has been made to do a threading G63 with a SERCOS spindle without
previously orienting it with M19.
SOLUTION
Program M19 before doing the threading.
1491
'Wrong probe number'
DETECTION
During execution.
CAUSE
The probe number selected with function #SELECT PROBE is wrong.
SOLUTION
The selected probe number must be either 1 or 2.
1492
'There is no digital input associated with the probe (PRBDI1/2)'
DETECTION
During execution.
CAUSE
The possible causes are:
• A measurement has been taken with function G100, but there is no digital probe
input associated with the probe.
• A probe has been selected using the instruction #SELECT PROBE, but there is
no digital input associated with that probe.
SOLUTION
Associate a digital input with the probe using machine parameter PRBDI1/2.
Summary of Contents for CNC8 070
Page 1: ...CNC8070 R EF 0402 ERROR SOLUTIONS...
Page 2: ......
Page 4: ......
Page 6: ......
Page 84: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 78 of 128 Errors 1000 1999...
Page 110: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 104 of 128 Errors 6000 6999...
Page 116: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 110 of 128 Errors 7000 7999...
Page 130: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 124 of 128 Tool and tool magazine table...
Page 133: ...CNC8070 REF 0402 ERROR SOLUTIONS Page 127 of 128...
Page 134: ...CNC8070 REF 0402 ERROR SOLUTIONS Page 128 of 128...