![Fagor CNC8 070 Error Code List Download Page 20](http://html1.mh-extra.com/html/fagor/cnc8-070/cnc8-070_error-code-list_3215668020.webp)
CNC8070
R
EF
. 0402
OF
128
E
RROR
SOLUTIONS
Page 14 of 128
Errors 1000-1999
1050
'Considering the tool offsets, it exceeds the data range'
DETECTION
During execution.
CAUSE
The tool dimensions exceed the maximum values.
SOLUTION
Modify the tool dimensions.
1052
'Values resulting from the measurement out of range'
DETECTION
During execution.
CAUSE
When taking a measurement with function G100, the obtained value is too large either
for the coordinate where it probed, either for the offset obtained in that probing move.
SOLUTION
The value obtained in that probing move must be between (-2147483647,
2147483646)
1054
'Nonexistent fixture'
DETECTION
During execution.
CAUSE
The programmed fixture index is wrong.
SOLUTION
The value of the fixture index must be more than zero and less than ten.
1055
'D and the tool radius cannot be modified in the same block'
DETECTION
During execution.
CAUSE
An attempt has been made to write the "V.G.TOR" variable in the same block where
a tool change or tool offset change is programmed.
SOLUTION
Programming in different lines.
1056
'Too many external variables'
DETECTION
During execution.
CAUSE
The maximum number of external variables (500) supported by the CNC has been
reached.
SOLUTION
Check the program.
1057
'Variable without reading permission'
DETECTION
During execution.
CAUSE
An attempt has been made from part-program or MDI to read a variable without
reading permission via program.
SOLUTION
The variable cannot be read from a part-program or MDI. The programming manual
indicates whether or not each variable has reading permission via program / MDI,
interface and PLC.
1059
'Variable without writing permission'
DETECTION
During execution.
CAUSE
The user has tried to write a variable without writing permission. An attempt has been
made from part-program or MDI to write a variable without writing permission via
program.
SOLUTION
The variable cannot be written. The variable cannot be written from a part-program
or MDI.
The programming manual indicates whether or not each variable has writing
permission via program / MDI, interface and PLC.
1060
'N label value out of range'
DETECTION
During execution.
CAUSE
An "N" block number has been defined that is not within the permitted range.
SOLUTION
The block number must be a positive value lower than 2147483646.
1061
'Nonexistent G function'
DETECTION
During execution.
CAUSE
The programmed G function does not exist.
SOLUTION
Check the program.
1062
'Incompatible G functions'
DETECTION
During execution.
CAUSE
Two G functions incompatible with each other have been programmed in the same
block.
SOLUTION
Program them in different blocks.
Summary of Contents for CNC8 070
Page 1: ...CNC8070 R EF 0402 ERROR SOLUTIONS...
Page 2: ......
Page 4: ......
Page 6: ......
Page 84: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 78 of 128 Errors 1000 1999...
Page 110: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 104 of 128 Errors 6000 6999...
Page 116: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 110 of 128 Errors 7000 7999...
Page 130: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 124 of 128 Tool and tool magazine table...
Page 133: ...CNC8070 REF 0402 ERROR SOLUTIONS Page 127 of 128...
Page 134: ...CNC8070 REF 0402 ERROR SOLUTIONS Page 128 of 128...