CNC8070
R
EF
. 0402
OF
128
E
RROR
SOLUTIONS
Page 102 of 128
Errors 6000-6999
6020
'CAN cycle overlap'
CAUSE
Failed reading of digital and analog inputs, counters and keyboard handwheels. A
node did not send the message in time.
SOLUTION
Verify in diagnosis mode that all the modules and the CAN error counter are
recognized. In case of error, make the relevant checks to assure the integrity of the
BUS CAN. If necessary, increase the cycle times (LOOPTIME, PLCFREQ).
Contact our technical service department.
6021
'Problems in CAN transmission'
CAUSE
Failed transmission of digital and analog outputs, etc. Possible BUS collapse.
SOLUTION
Verify in diagnosis mode that all the modules and the CAN error counter are
recognized. In case of error, make the relevant checks to assure the integrity of the
BUS CAN. If necessary, increase the cycle times (LOOPTIME, PLCFREQ).
Contact our technical service department.
6022
'Error when initializing the Axis counter'
DETECTION
During startup.
CAUSE
The counter does not exist.
SOLUTION
Check the parameters.
Contact our technical service department.
6023
'Error when initializing the Handwheel counter'
DETECTION
During startup.
CAUSE
The counter does not exist.
SOLUTION
Check the parameters.
Contact our technical service department.
6024
'Error when initializing the Keyboard Handwheel'
DETECTION
During startup.
CAUSE
The handwheel input does not exist.
SOLUTION
Check the parameters.
Contact our technical service department.
6025
'Checksum error at the COMPCI'
CAUSE
Error in the checksum control of the data of the digital or analog outputs sent from
the PC to the COMPCI through the Common RAM.
Type of module
SOLUTION
Contact our technical service department.
6026
'Hardware error at the COMPCI'
DETECTION
During system startup.
CAUSE
Error during the hardware test of the COMPCI.
SOLUTION
The diagnoses mode displays detailed information on this type of error. Verify that
the software version of the COMPCI is the right one.
Contact our technical service department.
6027
'Hardware error in remote CAN node'
DETECTION
During system startup.
CAUSE
Error during the hardware test of the remote nodes.
SOLUTION
The diagnoses mode displays detailed information on this type of error. Verify that
the software version of the node is the right one.
Contact our technical service department.
6028
'Error when accessing the RAM of the SERCON'
DETECTION
During startup.
CAUSE
RAM test failure.
SOLUTION
Contact our technical service department.
1
Analog outputs.
3
Digital outputs.
Summary of Contents for CNC8 070
Page 1: ...CNC8070 R EF 0402 ERROR SOLUTIONS...
Page 2: ......
Page 4: ......
Page 6: ......
Page 84: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 78 of 128 Errors 1000 1999...
Page 110: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 104 of 128 Errors 6000 6999...
Page 116: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 110 of 128 Errors 7000 7999...
Page 130: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 124 of 128 Tool and tool magazine table...
Page 133: ...CNC8070 REF 0402 ERROR SOLUTIONS Page 127 of 128...
Page 134: ...CNC8070 REF 0402 ERROR SOLUTIONS Page 128 of 128...