·82·
Remote modules
CNC 8060
CNC 8065
5.
(R
EF
: 1402)
RIOW REMOTE MODULES.
(CANOPEN
PROTOCOL).
5.6
RIOW-CANOPEN-STAND module. Leading (first) module.
The RIOW-CANOPEN-STAND module must be present in all the groups and must be the
first module of the group. This module is in charge of managing the internal bus of the group,
connecting the group to the system CAN bus and supplying power to the I/O modules through
the side jumpers with 24 V 10A. If when configuring the remote group, the consumption of
the I/O modules is higher, additional RIOW-PS24 modules must be added.
Power the module with an external 24V DC (between -15% and +20%) regulated power
supply. Using the wrong voltage may cause severe damage to the components.
4
8
1
5
2
6
3
7
C
A
D
B
56
78
12
34
ON
STOP
RUN
TX
RX
Overflow
I/O
24V
0V
CAN bus connection.
Address (node) of the element
and transmission speed.
Locking disk.
Power supply status indicator
LED's
Vo l t a g e s u p p l y fo r t h e I / O
modules.
Vo l t a g e s u p p l y fo r t h e I / O
modules. 0 V reference signal.
Vo l t a g e s u p p l y fo r t h e I / O
modules. Ground connection.
Module status indicator LED's
Voltage supply for the module.
0 V reference signal.
Voltage supply for the module.
Summary of Contents for CNC 8060
Page 1: ...Ref 1402 8060 8065 CNC Remote modules...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 16: ......
Page 20: ......
Page 22: ......
Page 147: ...Remote modules CNC 8060 CNC 8065 REF 1402 147...
Page 148: ...148 Remote modules CNC 8060 CNC 8065 REF 1402...