·114·
Remote modules
CNC 8060
CNC 8065
6.
(R
EF
: 1402)
REMOTE MODULE
RIOR
.
(CANOPEN PROTOCOL).
Dipswitch ·S42· Bus CAN. Address (node) of the element within the bus.
With the ·4· switch (ADD MSB), the positions or elements integrated in the CAN bus may
be expanded up to 32. Positions 0-15 are selected with ADD MSB=0 and positions 16-31
with ADD MSB=1.
Dipswitch ·S42·. CAN bus. Selecting the baudrate for the CANopen bus.
The transmission speed at the bus is defined in each node and they all must run at the same
speed. The speed is selected with switches ·2· and ·3· (CO BR).
The transmission speed depends on the total length of the bus. Using the following illustrative
values; assigning other values may cause communication errors due to signal distortion.
In order for any change of speed to be assumed, the corresponding module must be reset;
however, we recommend to change the speed while the modules and the CNC are off.
Dipswitch ·S42·. Update the software of the module.
Switch ·1· (ADD MSB) may be used to update the software of the module.
Dipswitch ·S43·. CAN bus. Line terminating resistor.
The terminating elements must have the resistor activated (position 1) but not the rest of the
elements (position 0).
1 2 3 4
ON
SO
F
T
CO B
R
A
DD M
S
B
DS ·4·
Address (node) of the element.
off
Positions 0-15 within the bus.
on
Positions 16-31 within the bus.
1 2 3 4
ON
SO
F
T
CO B
R
A
DD M
S
B
DS ·2·
DS·3·
Speed
Length of the CAN bus.
on
on
1000 kHz
Up to 20 meters.
off
on
800 kHz
From 20 to 40 meters.
on
off
500 kHz
From 40 to 100 meters.
off
off
250 kHz
From 100 to 500 meters.
1 2 3 4
ON
SO
F
T
CO B
R
A
DD M
S
B
DS ·1·
Address (node) of the element.
off
Module operative (running).
on
Update the software of the module.
Switch ·1· must only be set to "on" to update the software of the module. If the module starts up while
switch ·1· is in the "on" position, the CNC updates the software of the module and shows the message
"the software of the ... module will now be updated...".
The line terminating resistor identifies which are the elements that
occupy the ends of the CAN bus; i.e. the first and last physical
element in the connection.
0
1
Summary of Contents for CNC 8060