·130·
Remote modules
CNC 8060
CNC 8065
7.
(R
EF
: 1402)
R
E
MOTE MODU
LE RCS-S. (SERCOS PROTOCOL)
E188
INDUCTOSYN: Unknown error at E21A feedback.
E288
INDUCTOSYN: Unknown error at E21B feedback.
E388
INDUCTOSYN: Unknown error at E21C feedback.
E488
INDUCTOSYN: Unknown error at E21D feedback.
The ABSIND module has generated an unknown error. The error is likely due to bad performance. It
the error is repetitive and persistent, try replacing the ABSIND module associated with that feedback.
If the error persists, contact Fagor Automation S. Coop.
E189
INDUCTOSYN: Incoherent SSITYPE parameter with feedback device type connected to
E21A feedback.
E289
INDUCTOSYN: Incoherent SSITYPE parameter with feedback device type connected to
E21B feedback.
E389
INDUCTOSYN: Incoherent SSITYPE parameter with feedback device type connected to
E21C feedback.
E489
INDUCTOSYN: Incoherent SSITYPE parameter with feedback device type connected to
E21D feedback.
Check the dipswitch S50 of the ABSIND module. The selected value must be coherent with CNC
machine parameter SSITYPE and with the feedback type (inductosyn/resolver) connected to the
ABSIND module.
E192
wrong REFPULSE parameter at E21A feedback.
E292
wrong REFPULSE parameter at E21B feedback.
E392
wrong REFPULSE parameter at E21C feedback.
E492
wrong REFPULSE parameter at E21D feedback.
The value of machine parameter REFPULSE is inconsistent with the type of feedback connected.
Try changing its value. If the problem persists, contact Fagor Automation.
E193
Fagor digital feedback. Error on the absolute track E21A.
E293
Fagor digital feedback. Error on the absolute track E21B.
E393
Fagor digital feedback. Error on the absolute track E21C.
E493
Fagor digital feedback. Error on the absolute track E21D.
It cannot calculate the absolute position. Feedback pulses lost. The analog signal < 0.20 Vpp.
Check that the linear or rotary encoder is working at proper speed. Check mounting tolerances. Clean
the glass or the steel tape of the linear encoder. If none of the previous solutions solves the error, replace
the rotary encoder or reader head of the linear encoder.
E194
Fagor digital feedback. CPU error. E21A feedback.
E294
Fagor digital feedback. CPU error. E21B feedback.
E394
Fagor digital feedback. CPU error. E21C feedback.
E494
Fagor digital feedback. CPU error. E21D feedback.
Damaged rotary encoder or reader head of linear encoder. Replace the rotary encoder or the reader
head of the linear encoder.
E195
Fagor digital feedback. Error at the adjustment potentiometers. E21A feedback.
E295
Fagor digital feedback. Error at the adjustment potentiometers. E21B feedback.
E395
Fagor digital feedback. Error at the adjustment potentiometers. E21C feedback.
E495
Fagor digital feedback. Error at the adjustment potentiometers. E21D feedback.
Damaged rotary encoder or reader head of linear encoder. Replace the rotary encoder or the reader
head of the linear encoder.
E196
Fagor digital feedback. Image capturing sensor (CCD) error E21A feedback.
E296
Fagor digital feedback. Image capturing sensor (CCD) error E21B feedback.
E396
Fagor digital feedback. Image capturing sensor (CCD) error E21C feedback.
E496
Fagor digital feedback. Image capturing sensor (CCD) error E21D feedback.
Check mounting tolerances. Clean the glass or the steel tape of the linear encoder.
Damaged rotary encoder or reader head of the linear encoder; the CCD (Charge-Coupled Device) or
the LED (Light-Emitting Diode). Replace the rotary encoder or the reader head of the linear encoder.
E197
Fagor digital feedback. Supply voltage out of range. E21A feedback.
E297
Fagor digital feedback. Supply voltage out of range. E21B feedback.
E397
Fagor digital feedback. Supply voltage out of range. E21C feedback.
E497
Fagor digital feedback. Supply voltage out of range. E21D feedback.
The supply voltage must be between 5.3 V and 4.1 V. Check that the power cable of the rotary or linear
encoder is not damaged. Also check that the cable length is the right one and that the wiring connection
is the right one.
Summary of Contents for CNC 8060
Page 1: ...Ref 1402 8060 8065 CNC Remote modules...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 16: ......
Page 20: ......
Page 22: ......
Page 147: ...Remote modules CNC 8060 CNC 8065 REF 1402 147...
Page 148: ...148 Remote modules CNC 8060 CNC 8065 REF 1402...