Remote modules
CNC 8060
CNC 8065
5.
(R
EF
: 1402)
RIOW REMOTE MODULES.
(CANOPEN
PROTOCOL).
5.12.1
Elements (connectors).
Analog inputs for PT100 temperature sensors (2 inputs).
The module allows connecting sensors with a 2-wire or 3-wire interface.
Led ·BUS·. Data bus status.
Led ·ERR·. Error at the outputs.
3 wires.
2 wires.
Green LED's. Both inputs have an LED that turns on when
transmission at the bus is OK.
Red LED's. Both inputs have an LED that turns on when there is
an input reading error; reading out of range or broken cable.
R1+
RL1
R1-
SHIELD
R2+
RL2
R2-
SHIELD
Signal
Function
R1+
RL1
R1-
Signals of the PT100 sensor.
R2+
RL2
R2-
Signals of the PT100 sensor.
SHIELD
Grid.
The shield connectors are internally joined together and
are connected to the profile where the module is mounted
R+
R-
RL
R+
R-
RL
C
A
D
B
BUS
ERR
BUS
ERR
C
A
D
B
BUS
ERR
BUS
ERR