Remote modules
CNC 8060
CNC 8065
4.
(R
EF
: 1402)
·63·
RIO5 REMOTE MODULES.
(CANOPEN
PROTOCOL).
4.7
Numbering of the analog inputs and outputs and of the
temperature sensor inputs.
The CNC numbers the modules automatically according to the order of the remote groups
(·ADDRESS· selector of the power supply module).
When numbering the analog inputs, the CNC considers the inputs for the temperature sensor
(connector X5) as analog inputs. Therefore, when numbering the inputs, the CNC considers
that each module has 6 analog inputs; the four analog inputs plus the two temperature sensor
inputs.
The CNC machine parameters must be set to indicate the number of PT100 inputs and to
which analog inputs they are connected. A PT100 input is active if it has one of these
temperature sensors connected to it. Refer to the installation manual for further detail.
Group ·1·
4 analog inputs.
4 analog inputs.
2 PT100 inputs
Example.
Group ·1·
(address = 1)
Group ·2·
(address = 2)
Analog inputs.
PT100 inputs.
1 ·· 4
5 ·· 6
7 ·· 10
11 ·· 12
Analog outputs.
1 ·· 4
5 ·· 8
POWER
ANALOG I/O
X1
CHS
GN D
24V
S PEED
1
0
ADDRES S
E RR
RUN
CAN
0
1
LT
GN D
L
S H
H
S H
GN D
L
S H
H
S H
X2
X3
01
01
SH
X4
RL1
R1
R1
RF1
S H
X5
12
I1
I1
SH
12
GN D
X6
POWER
ANALOG I/O
X1
CHS
GN D
24V
SPE ED
1
0
A DDRESS
ERR
RUN
CA N
0
1
LT
GN D
L
SH
H
SH
GN D
L
SH
H
SH
X2
X3
01
01
SH
X4
RL1
R1
R1
RF1
SH
X5
12
I1
I1
S H
12
GN D
X6
Group ·2·
4 analog inputs.
4 analog inputs.
2 PT100 inputs
Summary of Contents for CNC 8060
Page 1: ...Ref 1402 8060 8065 CNC Remote modules...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 16: ......
Page 20: ......
Page 22: ......
Page 147: ...Remote modules CNC 8060 CNC 8065 REF 1402 147...
Page 148: ...148 Remote modules CNC 8060 CNC 8065 REF 1402...