English
English
(*)
1 dispenser unit machines only.
The undercup gasket is dirty with coffee
residue.
Leak from edge of filter-holder (
7
).
Clean with the supplied brush.
CAUSE
No electricity.
Wrong position of the main switch (
4
).
Only for 2-group machines.
DEFECT
The coffee machine does not function and the
indicator (
18
) is off.
The coffee machine does not heat up.
REMEDY
Check that the electricity is on.
Check the position of the main switch (
1
).
Turn the main switch knob (
1
) to position 2
Direct intervention by the customer
In order to avoid unnecessary costs, ensure that the problem occurring in the machine is not included in the following table before calling the servicing
department.
Defects - Malfunctions
Drainage tank clogged.
Water leaks from under the machine.
Clean the tank.
Coffee grinds too coarse.
Coffee too old.
Coffee flow time too short.
Grind the coffee more finely.
Change the coffee.
No water in tank.
Fill up tank.
Check position of water supply tap.
Tank level indicator light (
11
) ON flashing,
dispensing disabled.
Boiler load time-out.
Switch the machine ON and OFF. If this
doesn’t solve the problem, contact the Service
personnel.
Boiler level indicator light (
12
) ON flashing.
Machine at working temperature indicator
light (
17
) ON flashing.
Switch the machine ON and OFF. If this
doesn’t solve the problem, contact the Service
personnel.
Pressure time-out.