background image

GENERAL WARNINGS FOR PEOPLE SAFETY

THANK YOU

Thank you for purchasing a Fadini product. 
Please read these instructions carefully before using this 
appliance. The instructions contain important information 
which will help you get the best out of the appliance and 
ensure safe and proper installation, use and maintenance.  
Keep this manual in a convenient place so that you can always 
refer to it for the safe and proper use of the appliance.

INTRODUCTION 

This operator is designed for a specific scope of applications as 
indicated in this manual, including safety, control and signaling 
accessories as minimum required with Fadini equipment. 

 Any 

applications not explicitly included in this manual may cause 
operation problems or damages to properties and people. 

 

Meccanica Fadini snc is not liable for damages caused by the 
incorrect use of the equipment, or for applications not included 
in this manual or for malfunctioning resulting from the use of 
materials or accessories not recommended by the 
manufacturer. 

 The manufacturer reserves the right to make 

changes to its products without prior notice. 

 All that is not 

explicitly indicated in this manual is to be considered not 
allowed.

BEFORE INSTALLATION

Before commencing operator installation assess the suitability 
of the access, its general condition and the structure. 

 Make 

sure that there is no risk of impact, crushing, shearing, 
conveying, cutting, entangling and lifting situations, which 
may prejudice people safety. 

 Do not install near any source of 

heat and avoid contacts with flammable substances. 

 Keep all 

the accessories able to turn on the operator (transmitters, 
proximity readers, key-switches, etc) out of the reach of the 
children. 

 Transit through the access only with stationary 

operator. 

 Do not allow children and/or people to stand in the 

proximity of a working operator. 

 To ensure safety in the 

whole movement area of a gate it is advisable to install 
photocells, sensitive edges, magnetic loops and detectors. 

 

Use yellow-black strips or proper signals to identify dangerous 
spots. 

 Before cleaning and maintenance operations, 

disconnect the appliance from the mains by switching off the 
master switch. 

 If removing the actuator, do not cut the 

electric wires, but disconnect them from the terminal box by 
loosening the screws inside the junction box.

INSTALLATION

All installation operations must be performed by a qualified 
technician, in observance of the Machinery Directive 
2006/42/CE and safety regulations EN 12453 - EN 12445. 

Verify the presence of a thermal-magnetic circuit breaker 0,03 
A - 230 V - 50 Hz upstream the installation. 

 Use appropriate 

objects to test the correct functionality of the safety 
accessories, such as photocells, sensitive edges, etc. 

□ 

Carry out 

a risk analysis by means of appropriate instruments measuring 
the crushing and impact force of the main opening and closing 
edge in compliance with EN 12445. 

 Identify the appropriate 

solution necessary to eliminate and reduce such risks. 

 In case 

where the gate to automate is equipped with a pedestrian 
entrance, it is appropriate to prepare the system in such a way 
to prohibit the operation of the engine when the pedestrian 
entrance is used. 

 Apply safety nameplates with CE marking 

on the gate warning about the presence of an automated 
installation. 

 The installer must inform and instruct the end 

user about the proper use of the system by releasing him a 
technical dossier, including: layout and components of the 
installation, risk analysis, verification of safety accessories, 
verification of impact forces and reporting of residual risks.

INFORMATION FOR END-USERS

The end-user is required to read carefully and to receive 
information concerning only the operation of the installation 
so that he becomes himself responsible for the correct use of it. 

 The end-user shall establish a written maintenance contract 

with the installer/maintenance technician (on -call). 

 Any maintenance operation must be done by qualified 

technicians. 

 Keep these instructions carefully.

WARNINGS FOR THE CORRECT OPERATION OF THE 
INSTALLATION

 

For optimum performance of system over time according to 
safety regulations, it is necessary to perform proper 
maintenance and monitoring of the entire installation: the 
automation, the electronic equipment and the cables 
connected to these. 

□ 

The entire installation must be carried 

out by qualified technical personnel, filling in the Maintenance 
Manual indicated in the Safety Regulation Book (to be 
requested or downloaded from the site 
www.fadini.net/supporto/downloads). 

 Operator: 

maintenance inspection at least every 6 months, while for the 
electronic equipment and safety systems an inspection at least 
once every month is required. 

 The manufacturer, Meccanica 

Fadini snc, is not responsible for non-observance of good 
installation practice and incorrect maintenance of the 
installation.

DISPOSAL OF MATERIALS

Dispose properly of the packaging materials such as 
cardboard, nylon, polystyrene etc. through specializing 
companies (after verification of the regulations in force at the 
place of installation in the field of waste disposal). Disposal of 
electrical and electronic materials: to remove and dispose 
through specializing companies, as per Directive 2012/19/UE. 
Disposal of substances hazardous for the environment is 
prohibited.

UE DECLARATION OF CONFORMITY (DoC)

Manufacturer: 

Meccanica Fadini snc

Address:   

Via Mantova, 177/A - 37053 Cerea - VR - Italy

declare that the DoC is issued under our sole responsibility and 
belongs to the following product:

Control unit model 

ELPRO S50-T4

is in conformity with the relevant Union harmonisation legislation:
- Electromagnetic Compatibility Directive 2014/30/UE
- Low Voltage Directive 2014/35/UE

Cerea, 13/10/2017

Meccanica Fadini s.n.c.

Responsible Manager

GB

CONTROLLER FOR TALOS M50

ANTI-TERRORISM RETRACTABLE BOLLARDS

Elpro S50-T4

7

Summary of Contents for Elpro S50-T4

Page 1: ...OMATIQUE OU SEMI AUTOMATIQUE PREPARE POUR HORLOGE EXTERNE FONCTION PAS PAS HOMME MORT F R AMPEL MIT 3 LICHTERN VORGESEHEN AUTOMATISCH ODER HALBAUTOMATISCH F R EXTERNE UHR VORGESEHEN SCHRITT F R SCHRIT...

Page 2: ...i ecc Eseguire una attenta analisi dei rischi utilizzando appositi strumenti di rilevazione di impatto e schiacciamento del bordo principale di apertura e chiusura secondo quanto indicato nella normat...

Page 3: ...L2 1 L1 6 T3 22 A2 4T2 2 T1 5 L3 21 L3 A1 3 L2 1 L1 25 84 25 84 21 20 19 19 73 75 74 73 finecorsa apertura TALOS 2 cavo grigio filo bianco finecorsa chiusura TALOS 2 cavo blu filo bianco finecorsa ap...

Page 4: ...nzioni 9 Gestione semaforo vedere riquadro delle funzioni 10 ON Lampeggiatore spento in pausa 11 ON Richiude in pausa dopo passaggio fotocellule 12 ON Tempo di lavoro massimo 90 s OFF 18 s Simbologia...

Page 5: ...W max di segnalazione del movimento Uscita 24 Vdc Motori Finecorsa T3 TEMPO DI PAUSA 1 s 180 s T1 TEMPO DI LAVORO 1 s 22 s 55 56 Led di segnalazione Uscita per led a luce intermittente sempre funzion...

Page 6: ...i nessun comando anche radio sino allo scadere del tempo impostato sull orologio allo scadere del quale dopo il tempo di pausa seguir la salita automatica DIP SWITCH N 8 e N 9 Schedina semaforo ad inn...

Page 7: ...pact force of the main opening and closing edge in compliance with EN 12445 Identify the appropriate solution necessary to eliminate and reduce such risks In case where the gate to automate is equippe...

Page 8: ...2 Contactor LOWERING M2 6 T3 22 A2 4T2 2 T1 5 L3 21 L3 A1 3 L2 1 L1 6 T3 22 A2 4T2 2 T1 5 L3 21 L3 A1 3 L2 1 L1 25 84 25 84 21 20 19 19 73 75 74 73 limit switch opening TALOS 2 grey cable white wire l...

Page 9: ...affic lights control see functions box 10 ON Flasher off in dwell time 11 ON Close in dwell time after passing between photocells 12 ON Motor run time max 90 s OFF 18 s Symbols NO Contact NC Contact L...

Page 10: ...lways on blinking during the rising and lowering movements of the post and with the post in standing position They go off with post in down position 200 mA for the accessories LEDs or BEEPER COMMON LE...

Page 11: ...further command pulsing even by remote control is not accepted by the system until the time pre set on the clock is expired On expiring of it and after the pre set dwell time the post rises automatic...

Page 12: ...en utilisant instruments de d tection de l impact et crasement du bord principale d ouverture et fermeture conform ment aux normes EN 12445 D finir les solutions appropri es pour liminer ou r duire t...

Page 13: ...e course ouverture TALOS 1 c ble gris fil blanc fin de course fermeture TALOS 1 c ble bleu fil blanc 73 74 75 F 20 A MOTEUR 2 borne escamotable 230 V monophas 19 20 21 COMMUN M2 F 20 A 76 77 78 MOTEUR...

Page 14: ...stion du feu de circulation voir le tableau des fonctions 9 Gestion du feu de circulation voir le tableau des fonctions 10 ON Lampe clignotante teinte en pause 11 ON Referme en pause apr s le passage...

Page 15: ...endant le mouvement de mont e et de descente et en arr t avec la borne en position lev e Elles s teintent avec la colonne baiss e COMMUN LED ET OU BEEPER LED 51 52 53 MOTEUR 1 Borne escamotable 1 16 1...

Page 16: ...s longue Il n acceptera plus aucune commande m me radio jusqu l xpiration du temps tabli sur l horloge A l xpiration de ce temps apr s le temps de pause il y aura la mont e automatique DIP SWITCH N 8...

Page 17: ...etc F hren Sie eine sorgf ltige Risikoanalyse unter Verwendung geeigneter Instrumenten zur Erkennung von Schlag und Druck der Vorderkante des ffnen und Schlie en wie in EN 12445 festgelegt Identifizi...

Page 18: ...1 14 15 26 14 15 26 Contactor RISING M2 Contactor LOWERING M2 6 T3 22 A2 4T2 2 T1 5 L3 21 L3 A1 3 L2 1 L1 6 T3 22 A2 4T2 2 T1 5 L3 21 L3 A1 3 L2 1 L1 25 84 25 84 21 20 19 19 73 75 74 73 ffnung Endscha...

Page 19: ...ionen 9 Ampel Steuerung Sehen Sie Abschnitt Funktionen 10 ON Blinkleuchte Off in Pause 11 ON Es schlie t wieder in Pause nach Durchgang durch Lichtschranke 12 ON Max Betriebszeit 90 s OFF 18 s Symbole...

Page 20: ...LOS 4 graunes Kabel wei er Draht Schlie ung Endschalter TALOS 4 blaues Kabel wei er Draht POLLER 1 MOTOR 1 16 17 18 M1 COMMON POLLER 2 MOTOR 2 19 20 21 COMMON M2 POLLER 3 MOTOR 3 31 32 33 COMMON M3 PO...

Page 21: ...ies mit zweimaligem kurzen Blinken gefolgt von einer l ngeren Pause Bis nach Ablauf der auf der Uhr eingestellten Zeit wird es kein andere Befehl mehr angenommen auch nicht ber die Fernbedienung nachd...

Page 22: ...Elpro S50 T4 22...

Page 23: ...20 C 55 C Solenoid valve power supply 230 Vac 50 Hz Beeper output 230 Vac 100 W GB CARACTERISTIQUES TECHNIQUES Alimentation carte monophas e 230 Vac 10 50 Hz Alimentation carte triphas e 400 Vac 10 50...

Page 24: ...www fadini net IT Direttiva 2012 19 UE Smaltimento dei materiali elettrici ed elettronici VIETATO GETTARE NEI RIFIUTI MATERIALI NOCIVI PER L AMBIENTE GB Directive 2012 19 UE Disposal of electric and e...