MASTER-T commands leaf 1

(Default).

MASTER-T commands leaf 2

P1

P2

t

P1

P2

t

In all LEDs OFF status, press and hold
down push-button P1, and press
push-button P2 - LED A begins to
flash.

Using push-button P2, move from LED 1 to LED 2 according to the
type of leaf management you require, as described below.

12.4.1 Leaf 1 management with MASTER-T or SLA-

VE-T board

P1

P2

t

t

Press push-button P1 again to exit.

P1

P2

t

In all LEDs OFF status, press push-
button P1.
LED 

A

 will light up together with LED

4

.

12.4.2   Function Logic

P1

P2

t

P1

P2

t

Press push-button P2, for a choice
of 4 different function logics.

A1

automatic

A2

safety

A3

Stepped automatic

A4

Stepped semi-automatic
(default)

ÜÜ

Press push-button P1 again and
LED 

B

 will light together with LED 

1

.

12.4.3   Pause Times

Press push-button P2, for a choice
of 4 different pausetimes.

B1

5 seconds (default)

B2

10 seconds

B3

20 seconds

B4

30 seconds

P1

P2

t

P1

P2

ÜÜ

Press push-button P1 again and
LED 

C

 will light together with LED 

3

.

12.4.4   Opening/Closing Delay

Press push-button P2, for a choice
of 4 different delays.

C1

op. 0 sec / cl. 0 sec

C2

op. 2 sec / cl. 2 sec

C3

op. 2 sec / cl. 4 sec (default)

C4

op. 2 sec / cl. 8 sec

P1

P2

t

ÜÜ

P1

P2

t

Press push-button P1 again and
LED 

D

 will light together with LED 

3

.

12.4.5   Static Force

Press push-button P2, for a choice
of 4 different static forces.

D1

low

D2

medium low

D3

medium high (default)

D4

high

P1

P2

t

P1

P2

t

ÜÜ

Summary of Contents for MASTER-T

Page 1: ...TER T SLAVE T carta riciclata 100 per la natura for nature recycled paper 100 ist umweltfreundlich 100 Altpapier para la naturaleza 100 papel reciclado papier recycl 100 pour la nature voor de natuur...

Page 2: ...atmayoccurduringuse 10 TheinstallationmustconformtoStandardsEN12453andEN12445 Fornon EUcountries toobtainanadequatelevelofsafety theStandards mentionedabovemustbeobserved inadditiontonationallegalregu...

Page 3: ...ve cycles 30 1 Recovery time 2 for each completed cycle 1 Enclosure protection class IP 55 Transformer power 180 VA Motor max current 15A Operating ambient temperature 20 C 55 C Protection fuses 1 fus...

Page 4: ...2 Vdc flashing lamp Fig 4 Differential thermal breaker Notes 1 To lay electric cables use adequate rigid and or flexible tubes 2 To avoid any kind of interference always separate low voltage connectio...

Page 5: ...accessories and pulse generators will be connected and the SLAVE T units near the DOMO operators using 4 expansion bolts and their fixing screws Route the electric cables to the bottom of the box usi...

Page 6: ...J4 J2 F1 J6 P1 Programming push button Function P2 Programming push button Value F1 Battery and motor fuse F20A J1 Accessories terminal board J2 Not used J3 Motor connection terminal board J4 Connect...

Page 7: ...lock command Device with NC contact 1 4 FSW OP Opening safety devices contact Photocells e g SAFEBEAM 1 5 FSW CL Closing safety devices contact Photocells e g SAFEBEAM 1 6 BUS MASTER T SLAVE T connect...

Page 8: ...act have the same function they must be connected to each other in series Fig 10 Connection of 2 NA contacts in parallel Fig 11 N B If two devices with NA contact have the same function theymustbeconn...

Page 9: ...sh button P1 commands an OPEN A Whencheckshavefinished onceagainpresspush buttonP2to exit the inputs status function LED status Steady light Slow flashing lights every second Rapid flashing lights eve...

Page 10: ...automatic A2 safety A3 Stepped automatic A4 Stepped semi automatic default Press push button P1 again and LED B will light together with LED 1 12 4 3 Pause Times Press push button P2 for a choice of4...

Page 11: ...ht Make sure that the gate is closed and operatorslocked 12 4 8 Complete learning Ifyoupresspush buttonP2formorethan 3 seconds leaf 1 begins to move You can command the following functions with subseq...

Page 12: ...ries 12 5 Status of indicator light If you wish to use a 12V 0 5W indicator light terminal 9 11 of J1 seeFig 8 thefollowingtableshowsthestatusesoftheindicator light according to gate position Tab 4 St...

Page 13: ...ING SAFETY DEVICES STOP PULSES Table 5 c CLOSED Opens leaf ves and re closes after pause time No effect OPEN disabled No effect OPENING Reloads pause time Immediately reverses to open No effect Stops...

Page 14: ...the system is operating correctly and if necessary replace the faulty radio control Automated systemshut down Moves only by key operated command Faulty receiver card If the automated system is still...

Page 15: ......

Page 16: ...ppen van de apparaat gehandhaafd blijven zonder zich daardoor te verplichten deze publicatie bij te werken Timbro del Rivenditore Distributor s Stamp Timbre de l Agent Fachh ndlerstempel Sello del Rev...

Reviews: