Connection of DECODER, MINIDEC, RP cards
Insert the DECODER, MINIDEC or RP decoding card in the block
connector J6 (Fig. 7), with the components facing up (Fig. 13
shows the connection of cards RP433DS).
The connector has both the OPEN A total-opening signal and the
OPEN B partial-opening signal, therefore you can use an RP2 868
SLH receiver that enables management of two separate contacts.
For programming the decoding cards, consult the individual
instructions.
When the LEDs light up, this indicates the inputs status as shown
in Tab. 3.
12.3 Status of inputs
The MASTER-T board has a function for checking the status of
inputs on the terminal board.
In all LEDs OFF status (LEDs both with letters and numbers), press
the P2 push-button.
t
12.4 Programming
These are the basic settings of the MASTER-T board:
MASTER-T board
LEAF 1
Function logic:
A4
Pause times:
B1
Opening/closing delay:
C3
Static force:
D3
Speed:
E2
If you wish to execute customised programming (see par. from
12.4.1 to 12.4.6) and time-learning (see par. 12.4.7 and 12.4.8)
follow the steps in the next pages.
P1
P2
Notes
:
•
The status of LEDs with the gate closed at rest is shown in
bold
.
•
LED 1 is active only when BUS communication is present
between MASTER-T and SLAVE-T boards in systems with double-
leaf gates.
•
In the inputs status function, push-button P1 commands an
OPEN A.
When checks have finished, once again press push-button P2 to
exit the inputs status function.
LED status
Steady light
Slow flashing
(lights every
second)
Rapid flashing
(lights every 250
msec)
Light OFF
Tab. 2
- LED P status description
12.2 Diagnostics
LED "P" (see Fig.7) - visible from outside the enclosure - performs the
diagnostics function. LED statuses are 3 which differ according to
MASTER-T board and SLAVE-T board:
MASTER-T board
Indicates mains power
supplied and board
ready to use.
Not present.
Indicates thermal
protection activated. A
cycle can be
performed only after
waiting for at least 2
minutes.
Indicates no mains
power supplied. During
this stage, the system
does not work.
SLAVE-T board
Indicates BUS present
and MASTER-T board
synchronized.
Indicates mains
power supplied but
board not
synchronized (faulty
BUS)
Not present.
Indicates no mains
power supplied and
MASTER-T board not
synchronized (faulty
BUS)
12.1
Powering up the system
After making all the cable connections we described previously,
power up the system to enable diagnostics, check of inputs status
and programming.
12. START-UP
LED
Lighted
Off
(closed contact)
(open contact)
A = Open A Command active
Command inactive
B = Open B Command active
Command inactive
C = Stop
Command inactive
Command active
D = Fsw op
Safety devices
Safety devices
disengaged
engaged
E = Fsw cl
Safety devices
Safety devices
disengaged
engaged
1 = SLAVE-T
SLAVE-T present
SLAVE-T absent
and active
or inactive
Tab. 3
- Description of inputs status LEDs