EC DECLARATION OF CONFORMITY FOR MACHINES

(DIRECTIVE 98/37/EC)

Manufacturer:

FAAC S.p.A.

Address:

Via Benini, 1  - 40069  Zola Predosa BOLOGNA - ITALY

Declares that:

MASTER-T / SLAVE-T control board

• is built to be integrated into a machine or to be assembled with other machinery to create a machine under

the provisions of Directive 98/37/EC;

• conforms to the essential safety requirements of the following EEC directives:

73/23/EEC and subsequent amendment  93/68/EEC.
89/336/EEC and subsequent amendment  92/31/EEC and 93/68/EEC

and also declares that it is prohibited to put into service the machinery until the machine in which it will be
integrated or of which it will become a component has been identified and declared as conforming to the
conditions of Directive 98/37/EC.

Bologna, 01 January 2004

The Managing Director

A. Bassi

1) ATTENTION! To ensure the safety of people, it is important that you read

all the following instructions. Incorrect installation or  incorrect use of the
product  could  cause  serious harm   to people.

2) Carefully read the instructions before beginning to install the product.

3) Do not  leave packing materials (plastic, polystyrene, etc.)   within  reach of

children as  such materials  are  potential  sources  of  danger.

4) Store these instructions for  future reference.

5) This product was designed and built strictly for the use indicated in this

documentation. Any other use, not expressly indicated here, could
compromise the good condition/operation of the product and/or be a
source of danger.

6) FAAC declines all liability caused by improper use or use other than that for

which the automated system was intended.

7) Do not install the equipment in an explosive atmosphere: the presence of

inflammable gas or fumes is a serious danger to safety.

8) The mechanical parts must conform to the provisions of Standards EN 12604

and EN 12605.
For non-EU countries, to obtain an adequate level of safety, the Standards
mentioned above must be observed, in addition to national legal regulations.

9) FAAC is not responsible for failure to observe Good Technique in the

construction of the closing elements to be motorised, or for any deformation
that may occur during use.

10) The installation must conform to Standards EN 12453 and EN 12445.

 For non-EU countries, to obtain an adequate level of safety, the Standards
mentioned above must be observed, in addition to national legal regulations.

11) Before attempting any job on the system, cut out electrical power .

12) The mains power  supply of the automated system must be fitted with an all-

pole  switch with contact opening distance of 3mm or greater. Use of a 6A
thermal breaker with all-pole circuit break is recommended.

13) Make sure that a differential switch with threshold of 0.03 A is fitted upstream

of the system.

14) Make sure that the earthing system is perfectly constructed, and connect

metal parts of  the means of  the closure to it.

15) The automated system is supplied with an intrinsic anti-crushing safety

device consisting of a torque control. Nevertheless, its tripping threshold
must be checked as specified in the Standards indicated at point 10.

16) The safety devices (EN 12978 standard)  protect any danger areas against

mechanical movement Risks

, such as crushing, dragging, and shearing.

17) Use of at least one indicator-light (e.g. FAACLIGHT ) is recommended for

every system, as well as a warning sign adequately secured to the frame
structure, in addition to the devices mentioned at point “16”.

18) FAAC declines all liability as concerns safety and efficient operation of

the automated system, if system components not produced by FAAC are
used.

19)

For maintenance, strictly use original parts by FAAC.

20)

Do not in any way modify the components of the automated system.

21) The installer shall supply all information concerning manual operation of

the system in case of an emergency, and shall hand over to the user the
warnings handbook supplied with the product.

22) Do not allow children or adults to stay near the product while it is operating.

23) Keep remote controls or other pulse generators away from children, to

prevent the automated system from being activated involuntarily.

24)

Transit is permitted only when the automated system is idle.

25) The user must not attempt any kind of repair or direct action whatever

and contact qualified personnel only.

26) Maintenance: check at least every 6 months the efficiency of the system,

particularly the efficiency of the safety devices (including, where
foreseen, the operator thrust force) and of the release devices.

27) Anything not expressly specified in these instructions is not permitted.

WARNINGS FOR THE INSTALLER

GENERAL SAFETY OBLIGATIONS

Summary of Contents for MASTER-T

Page 1: ...TER T SLAVE T carta riciclata 100 per la natura for nature recycled paper 100 ist umweltfreundlich 100 Altpapier para la naturaleza 100 papel reciclado papier recycl 100 pour la nature voor de natuur...

Page 2: ...atmayoccurduringuse 10 TheinstallationmustconformtoStandardsEN12453andEN12445 Fornon EUcountries toobtainanadequatelevelofsafety theStandards mentionedabovemustbeobserved inadditiontonationallegalregu...

Page 3: ...ve cycles 30 1 Recovery time 2 for each completed cycle 1 Enclosure protection class IP 55 Transformer power 180 VA Motor max current 15A Operating ambient temperature 20 C 55 C Protection fuses 1 fus...

Page 4: ...2 Vdc flashing lamp Fig 4 Differential thermal breaker Notes 1 To lay electric cables use adequate rigid and or flexible tubes 2 To avoid any kind of interference always separate low voltage connectio...

Page 5: ...accessories and pulse generators will be connected and the SLAVE T units near the DOMO operators using 4 expansion bolts and their fixing screws Route the electric cables to the bottom of the box usi...

Page 6: ...J4 J2 F1 J6 P1 Programming push button Function P2 Programming push button Value F1 Battery and motor fuse F20A J1 Accessories terminal board J2 Not used J3 Motor connection terminal board J4 Connect...

Page 7: ...lock command Device with NC contact 1 4 FSW OP Opening safety devices contact Photocells e g SAFEBEAM 1 5 FSW CL Closing safety devices contact Photocells e g SAFEBEAM 1 6 BUS MASTER T SLAVE T connect...

Page 8: ...act have the same function they must be connected to each other in series Fig 10 Connection of 2 NA contacts in parallel Fig 11 N B If two devices with NA contact have the same function theymustbeconn...

Page 9: ...sh button P1 commands an OPEN A Whencheckshavefinished onceagainpresspush buttonP2to exit the inputs status function LED status Steady light Slow flashing lights every second Rapid flashing lights eve...

Page 10: ...automatic A2 safety A3 Stepped automatic A4 Stepped semi automatic default Press push button P1 again and LED B will light together with LED 1 12 4 3 Pause Times Press push button P2 for a choice of4...

Page 11: ...ht Make sure that the gate is closed and operatorslocked 12 4 8 Complete learning Ifyoupresspush buttonP2formorethan 3 seconds leaf 1 begins to move You can command the following functions with subseq...

Page 12: ...ries 12 5 Status of indicator light If you wish to use a 12V 0 5W indicator light terminal 9 11 of J1 seeFig 8 thefollowingtableshowsthestatusesoftheindicator light according to gate position Tab 4 St...

Page 13: ...ING SAFETY DEVICES STOP PULSES Table 5 c CLOSED Opens leaf ves and re closes after pause time No effect OPEN disabled No effect OPENING Reloads pause time Immediately reverses to open No effect Stops...

Page 14: ...the system is operating correctly and if necessary replace the faulty radio control Automated systemshut down Moves only by key operated command Faulty receiver card If the automated system is still...

Page 15: ......

Page 16: ...ppen van de apparaat gehandhaafd blijven zonder zich daardoor te verplichten deze publicatie bij te werken Timbro del Rivenditore Distributor s Stamp Timbre de l Agent Fachh ndlerstempel Sello del Rev...

Reviews: