E124S 17
532434 - Rev.A
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
Basic function
DEFAULT
SP
SPEED
Speed of movement.
01
…
10
(levels)
08
En
ENCODER
Enables/disables the encoder on both motors.
no
disabled,
Y
enabled
Y
(non-modifiable) if
cF
=
03
or
05
or
06
or
07
no
if
cF
=
00
or
01
or
02
or
04
no
(non-modifiable) if
cF
=
08
FA
OPENING LIMIT SWITCH
Enables/disables the opening limit
switches, to stop the automation or start the slowdown. Modi-
fying the value requires a new
SETUP
.
no
disabled,
01
to stop,
02
to start slowdown
no
FC
CLOSING LIMIT SWITCH
Enables/disables the closing limit
switches, to stop the automation or start the slowdown. Modi-
fying the value requires a new
SETUP
.
no
disabled,
01
to stop,
02
to start slowdown
no
Cd
CLOSING DELAY
NOT displayed if
Mn
=
1
. The delay is
applied to Leaf 1.
00
…
59
s Adjustment step: 1 s
The display subsequently changes to minutes and tens of seconds
(separated by a point), up to a maximum of
1.3
minutes.
1.0
…
1.3
Adjustment step: 10 s
E.g.
1.2
= 1 min and 20 s.
05
bu
BUS 2easy REGISTRATION
See the
§
specific section.
no
M2
MOTOR 2 OPERATION
NOT displayed if
Mn
=
1
. In this
function, b and - operate Motor 2 in hold-to-run mode.
++
OPEN (displaying
oP
),
--
CLOSE (displaying
cL
)
--
M1
MOTOR 1 OPERATION
In this function, b and - oper-
ate Motor 1 in hold-to-run mode.
++
OPEN (displaying
oP
),
--
CLOSE (displaying
cL
)
--
tL
SETUP
See the
§
specific section.
--
St
LEAVING THE PROGRAMMING MODE
Y
Exit saving the settings
no
Exit without saving the programming
After having confirmed using button
FF
, the display indicates the
STATUS of the automation:
Y
00
CLOSED
01
OPEN
02
STATIONARY THEN OPENS
03
STATIONARY THEN CLOSES
04
in PAUSE
05
OPENING
06
CLOSING
07
FAIL- SAFE in progress
08
VERIFYING BUS 2easy
09
PRE-FLASHING and then OPENS
10
PRE-FLASHING and then CLOSES
11
EMERGENCY OPEN
12
EMERGENCY CLOSE
HP
Hold Position
. (point flashing) SLEEP