16. OPERATION
■
OBSTACLE DETECTION BY BOARD or ENCODER
I
f an obstacle is detected during opening or closing,
the leaf reverses (ANTI-CRUSHING), then the automa-
tion stops.
ACCESSORIES
■
LED
Lights up during opening and stays on as long as the
automation remains open. Flashes during closing. It
is off when the automation is closed.
■
COURTESY LIGHT
Lights up during movements and remains on for the
set time (
t1
).
■
TRAFFIC LIGHT CONTROL
It lights up when the automation is opening and stays
on as long as it remains open.
OPERATING LOGICS
L
the
STOP
command has priority in all the logics and
stops the automation.
The
CLOSE
command always closes the automation.
■
E
SEMI-AUTOMATIC
This logic only uses the
OPEN
command.
OPEN
if the automation is closed, causes it to open.
OPEN
if the automation is open, causes it to close.
OPEN
during opening, stops the gate and the next
OPEN
command closes it.
OPEN
during closing, causes it to reopen.
The triggering of the photocells
during movement, re-
verses the gate.
■
EP
SEMI-AUTOMATIC STEP-BY-STEP
This logic only uses the
OPEN
command.
OPEN
if the automation is closed, causes it to open.
OPEN
if the automation is open, causes it to close.
OPEN
during opening or closing, stops the gate and
the next
OPEN
command reverses the direction.
The triggering of the photocells
during movement, re-
verses the gate.
■
S
aUTOMATIC SAFETY
This logic only uses the
OPEN
command.
OPEN
if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
COMMANDS
■
OPEN A
- Total motion
Total motion is 100% of the length of travel. In 2-leaf
automations, Leaf1
starts opening first (if the delay is
programmed).
■
OPEN B
- Partial motion
In single leaf automations, partial motion is 50% of
the length of travel.
In 2-leaf automations, partial motion is 100% of the
length of travel of Leaf1. Leaf1
starts opening first (if
the delay is programmed).
■
STOP
- Stops until the button is reset.
BATTERY OPERATION (IF PRESENT)
When there is no mains power, the automation oper-
ates on battery until the charge level drops to the
threshold value: 16 V
"
.
WARNING
The frequency at which the flashing light
flashes increases with every movement carried out in
battery operation mode. A warning can be also be
programmed on a dedicated output.
SLEEP mode
If the charge drops to the threshold
value, the board goes into
SLEEP
mode: automation
NOT operational, display off,
IN
LED flashing every 4
s. Normal operation resumes when the mains sup-
ply is restored.
DETECTION DEVICES
■
CLOSING PHOTOCELLS
The triggering of the photocells during closing, causes
the gate to open. An alternative operation can be
configured using function
Ph
in Advanced program-
ming: the triggering of the photocells stops the gate
immediately and opens it when they are released.
If they are engaged when the leaves are stationary, the closing
photocells prevent the gate from closing until they are released.
■
OPENING PHOTOCELLS
If the photocells are triggered, the automation is
stopped.
■
OPENING/CLOSING PHOTOCELLS
If the photocells are triggered, the automation is
stopped.
■
SENSITIVE EDGE SAFETY
I
f an obstacle is detected during opening or closing,
the leaf reverses for 2 s and then the automation stops.