2
Basic programming menu
Basic function
DEFAULT
][
Simply Connect
To enable Simply Connect, select a com-
munication channel (CH 1…4).
0
disabled,
1
(CH 1),
2
(CH 2),
3
(CH 3),
4
(CH 4)
0
cF
TYPE OF AUTOMATION
Select the type of actuator installed
(board loads the relative default configuration).
0
The letters
EP
indicate a "mixed" automation: 2 leaves with 2
different actuators (from Simply Connect).
00
no FAAC actuator
01
412, 413, 415, 770, 390, 770N
02
391
03
S700H/S800H
04
S418
05
S450H
06
S800H ENC
07
S2500 I
08
S800H without
encoder
dF
DEFAULT CONFIGURATION
Y
indicates if the programming
corresponds to the default settings. Select
Y
if you wish to
reload the default values for the type of automation.
Y
the programming corresponds to the DEFAULT settings
no
the programming does not correspond to the DEFAULT
settings
Y
LO
OPERATING LOGICS
E
E
Semi-automatic
EP
Semi-automatic step by
step
S
Automatic Safety
SA
Automatic Safety 2
SP
Automatic step by step
A1
Automatic 1
A
Automatic
AP
Automatic step by step
At
Automatic with timer
function
b
Semi-automatic b
bC
Mixed (Impulse open-
ing / Hold-to-run closing)
C
Hold-to-run
CU
Displayed if there
is a CUSTOM logic from
Simply Connect.
PA
PAUSE TIME A
Displayed only in logics with automatic clos-
ing. This function specifies the pause time if the automation
has been opened by the
OPEN A
command.
00
…
59
s Adjustment step: 1 s
The display subsequently changes to minutes and tens of seconds
(separated by a point) and the time is adjusted in 10 s steps, up
to the maximum value of
9.5
minutes.
E.g.
1.2
= 1 min and 20 s
30
Pb
PAUSE TIME B
Displayed only in logics with automatic clos-
ing. This function specifies the pause time if the automation
has been opened by the
OPEN B
command (adjustment similar
to
PA
)
30
Mn
NUMBER of MOTORS
enabled.
1
1 motor,
2
2 motors
2
F1
MOTOR 1 POWER
01
…
50
(levels)
25
if
cF
=
00
or
01
or
02
or
04
40
if
cF
=
03
or
06
or
08
35
if
cF
=
05
15
if
cF
=
07
F2
MOTOR 2 POWER
NOT displayed if
Mn
=
1
.
01
…
50
(levels)
25
if
cF
=
00
or
01
or
02
or
04
40
if
cF
=
03
or
06
or
08
35
if
cF
=
05
15
if
cF
=
07