1 8
E124S 32
532434 - Rev.A
1
2 x Pb 12 V - 4 Ah
90 x 70 x 108 mm
2
3
BATTERY
POWER
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
red (
+
)
black (–)
11. EMERGENCY BATTERIES
Use rechargeable lead batteries that can supply:
Volt-
age 20…28 V
"
,
Current 16 A max
.
To install, use the
BATTERY SUPPORT KIT
(see FAAC cata-
logue - includes the connection cables).
1. Remove the cover and set up the enclosure:
G
To prevent the risk of explosion due to the build up of
gas generated by lead batteries, drill a
∅
1 mm hole
in the enclosure. The hole must be at the top of the
battery compartment and must not allow water to get
into the enclosure.
2. Insert the support and rest the batteries on it.
3. Connect the cables supplied to the battery termi-
nals, following the polarity shown.
4. Make sure that the main power connector (
POWER
)
is already plugged in, then connect the batteries to
the
BATTERY
connector.
-
The battery operation signal can be enabled, in
programming, on a programmable output (OUT1,
OUT2).
-
Check the
BATTERY
LED (§ Diagnostics).
5. Replace the cover of the enclosure.
12. EXTERNAL POWER SUPPLY
As an alternative to the 230 V mains power supply, an
external stabilized power supply, which can supply
the following power, can be connected to the
BAT-
TERY
connector
:
Voltage 20…28 V
"
, Current 16 A max
L
Use programming via Simply Connect to disable the
battery charging function (only with Simply Connect).