Advanced programming menu
Advanced function
DEFAULT
bo
MAXIMUM FORCE AT INITIAL THRUST TIME
When it starts, the motor
operates at maximum power for the time set in this option.
01
…
10
s Adjustment step: 1 s.
02
03
if
cF
=
08
cS
CLOSING THRUST
This function assists the closing of the electric lock: it
pushes against the closing stop with maximum force for 2 s. DO NOT enable
the function if there is not a mechanical closing stop fitted.
Y
enabled,
no
disabled
no
(non-modifiable if
cF
=
01
, limit switches to stop)
rS
REVERSE STROKE FOR OPENING
NOT displayed if
FC
=
1
.
This function assists the release of the electric lock: it pushes against the
closing stop for 2 s before opening. DO NOT enable the function if there is
not a mechanical closing stop fitted.
The reverse stroke is NOT compatible with the closing stop limit switch, for this
reason it is not carried out if, after enabling it, you set
FC
=
1
.
Y
enabled,
no
disabled
no
EL
ELECTRIC LOCK ON LEAF 2
NOT displayed if
Mn
=
1
. This function has
to be enabled if the electric lock is installed on Leaf 2 (it is usually on Leaf 1).
Y
enabled,
no
disabled
no
Od
LEAF OPENING DELAY
NOT displayed if
Mn
=
1
. This delay is applied
to Leaf 2.
00
…
59
s Adjustment step: 1 s The display subsequently changes to
minutes and tens of seconds (separated by a point), up to a maximum of
1.3
minutes. E.g.
1.2
= 1 min and 20 s.
1.0
…
1.3
Adjustment step: 10 s
02
IP
REVERSE ON OBSTACLE
This function specifies the amount the leaf is
reversed after an obstacle has been detected.
Y
= partial reverse (for 2 s),
no
= complete reverse
no
r1
LEAF 1 DECELERATION
NOT displayed if
FA
and
FC
=
2
. Specifies the
deceleration space for Leaf 1 (% of the total stroke).
00
…
99
% Adjustment step: 1 %
30
20
if
cF
=
03
or
05
r2
LEAF 2 DECELERATION
NOT displayed if
Mn
=
1
, or if
FA
and
FC
=
2
.
Specifies the deceleration space of Leaf 2 (% of the total stroke).
00
…
99
% Adjustment step: 1 %
30
20
if
cF
=
03
or
05
PF
PRE-FLASHING
Enables/disables pre-flashing and specifies when it is
activated. The pre-flashing time is fixed: 3 s.
no
no
disabled
OC
for any movement
CL
when closing
OP
when opening
PA
when the pause time elapses
Ph
CLOSING PHOTOCELLS
Specifies the operation of the closing photocells.
Y
reopen when the photocells disengage
no
reopen immediately
no
Ad
ADMAP FUNCTION
Enables/disables operation in accordance with French
standard NFP 25/362.
Y
enabled,
no
disabled
no