The Standard Reverse Terminal is for applications when an external device may be used as a standard reverse.  For example:  
Photo Sensors connected to this terminal will operate the same as a Reverse Loop.  This connection should not be used for 
Safety Reverse Devices.  Use Edge and Photo inputs for proper Safety connections. 

O

PEN

, C

LOSE

, S

TOP

 C

ONNECTIONS

The gate operator may use an external Open, Close, Stop (3-Button) to control the gate.  The controller has built-in button 
controls above each terminal for setup and testing. 

 

E

XTERNAL

 R

ESET

 C

ONNECTION

An external Reset Button may be connected to the Reset Terminal and used to reset the operator during Hard Shutdown 
situations.  During a Hard Shutdown, the operator can only be reset through the reset input or reset button on the left side of 
the controller.  The Reset Input can also be used during installation to reset the operator settings. 
 

Standard Reverse Input: 

1.  Input is inactive when gate is closed or in the open cycle. 

2.  When gate is open and Time Delay Close is ON, an input will 

reset the Time Delay Close. 

3.  When gate is open and Time Delay Close is OFF, an input will 

prevent the gate from closing. 

4.  When gate is closing, an input will reverse the gate. 

 
Connecting Standard Reverse Devices: 

1.  Connect to STD REVERSE and COMMON 

2.  For Devices that use 24VDC power, connect power to +24VCD 

and COMMON 

Standard 

REVERSE 

Device 

Open, Close, Stop Input: 

1.  OPEN:  Allows external input to OPEN gate. 

2.  CLOSE:  Allows external input to CLOSE gate. 

3.  STOP:  Allows external input to STOP gate. 

 
Connecting Standard Reverse Devices: 

1.  Connect Open Button to OPEN and COMMON. 

2.  Connect Close Button to CLOSE and COMMON. 

3.  Connect Stop Button to STOP and COMMON. 

OPEN 

CLOSE 

STOP 

Reset Input: 

1.  Allows external input to reset gate operator during a Hard 

Shutdown. 

2.  Allows external input to reset operator settings during 

installation. 

 
Connecting External Reset Devices: 

1.  Connect Reset Button to RESET and COMMON. 

External 

Reset 

DSW2000 Swing Gate Operator 

20 

Summary of Contents for DSW2000

Page 1: ...nal Inc West Coast Operations 357 S Acacia Avenue 357 Fullerton CA 92831 800 221 8278 American Built www FAACUSA com Revision D FAAC International Inc Headquarter East Coast Operations 5151 Sunbeam Ro...

Page 2: ...ATOR ADJUSTMENTS Reverse Sensitivity Adjustment 14 Reverse Sensitivity Shutdown 14 Close Time Delay Adjustment 15 DIP Switch Settings 15 ACCESSORY CONNECTIONS Accessory Wire Overview 16 Edge Sensor Co...

Page 3: ...derstand the manufacturer can not be held responsible for damage or injury caused by improper erroneous or unreasonable use Failure to comply with these guidelines may create a dangerous situation and...

Page 4: ...of sight with the gate and its travel Activating devices must be installed a minimum of 10 feet away from the gate Be sure to mount ALL operating devices clearly out of reach of through gate Controls...

Page 5: ...nce some devices only cover a select area For example a photo beam will not cover the full height of a gate fence area Refer to the diagram below Contact Sensors Edge Sensors Contact sensors generally...

Page 6: ...te to align the arm with the output shaft and insert the Sheer Pin 3 Press the Release Handle down until tight 4 Attach the top arm cap cover 5 Turn power on Make sure the gate and all reversing devic...

Page 7: ...on of a wall or fence system that controls entrance and or egress by people or vehicles and completes the perimeter of a defined area VEHICULAR SWING GATE OPERATOR Or System A vehicular gate operator...

Page 8: ...fore installing the gate operator Add safety devices such as warning signs photo eyes and reverse edges to help prevent injuries or death Reduce all pinch points and protect all entrapment areas If pe...

Page 9: ...ll conduits may be located in the concrete pad terminating directly under the operator Extend each conduit a minimum of 1 above the level of the concrete pad See the Conduit Location diagram below It...

Page 10: ...HE GATE ARM To determine the arm length in a standard location 1 Make sure the Arm Operator and gate are level with each other 2 A Measure 46 from gate hinge out on gate 3 B Measure 35 5 for Long Arm...

Page 11: ...imit Cam to until it activates the top switch The switch will click when activated Tighten the Limit Cam screw if needed 4 Readjust Limits to fine tune the gate position 5 Make sure each limit cam hit...

Page 12: ...wer should be supplied from a circuit breaker panel and must have its own dedicated circuit breaker This supply must include a green ground conductor 3 Only use U L approved 14 AWG or larger 600 Volt...

Page 13: ...r DO NOT USE THESE POWER OUTLETS FOR INSTALLATION OR SERVICE TOOLS Each plug supplies 110 VAC when AC power is active to the gate operator If AC is not available the power plugs will not supply power...

Page 14: ...and the Slave operator Recommended Wire Outdoor Rated CAT 5 Cable 5 Using the supplied RS422 connectors color connect each wire MASTER ORANGE WHITE to SLAVE ORANGE WHITE Pin 1 to Pin 6 MASTER ORANGE...

Page 15: ...the gate to stop the gate while in travel The gate should stop and enter a Soft Shutdown upon striking the object 10 Repeat steps 2 6 until the correct sensitivity adjustment is found REVERSE SENSITI...

Page 16: ...the alarm in shutdown applications 2 Anti Tailgate OFF Gate opens and closes normal ON Uses loops to control vehicles individually 3 Master Slave OFF Operator is set as a Master Primary ON Operator is...

Page 17: ...TIONS ACCESSORY WIRE OVERVIEW CLOSE Photo Cell OPEN Photo Cell O P E N E D G E C L O S E E D G E Radio Receiver OPEN CLOSE STOP FIRE LOCK Card Access 1 2 3 4 5 6 7 8 9 0 Key Box 1 2 3 4 5 6 7 8 9 0 Ph...

Page 18: ...en cycle 2 An input during open cycle will stop and reverse the gate to the full closed position and enter a soft shutdown 3 NOTE If the gate was initially activated by a time clock with a contact clo...

Page 19: ...sensors shall be located where a risk of entrapment or obstruction exists such as the perimeter reachable by a moving gate or barrier and arm pinch point and entrapment areas Use caution when installi...

Page 20: ...tion to reset the operator settings Standard Reverse Input 1 Input is inactive when gate is closed or in the open cycle 2 When gate is open and Time Delay Close is ON an input will reset the Time Dela...

Page 21: ...n open position gate will remain open until an external input is made This prevents the Fire Input from closing the gate if in the open position Connecting Access Devices 1 Connect Fire Lock Control r...

Page 22: ...Radio Receivers 1 Connect Radio Relay to RADIO N O and RADIO COMMON 2 If the Radio Receiver uses 24VDC connect Radio Power to RADIO PWR 24VDC and RADIO PWR 24VDC 3 Use the following chart for standard...

Page 23: ...motion if desired 2 Allows external Warning Light to be active during gate motion Connecting External Alarm Warning Light 1 Connect Warning Light to WARNING NO and WARNING COM 2 Connect Alarm to ALARM...

Page 24: ...op slot should be 1 4 wide Cut diagonal corner slots to protect the wire insulation and keep the wire from changing directions quickly 3 Install loop wire Recommended Wire 14 AGW to 18 AGW Stranded XL...

Page 25: ...pen Loop Plug detector into left socket Make sure detector is secure and snapped in 4 Set different frequencies for each loop detector 5 Follow the directions provided with the PLD1500 for more detail...

Page 26: ...oose connection 2 Start the operator watch Sensor 1 and Sensor 2 at startup They should both blink before turning solid If only one blinks then the non blinking sensor is not being seen 3 Remove the m...

Page 27: ...s reference manuals and warning label instructions 2 Vehicular gates are for vehicles only Pedestrians must use a separate entrance Keep all pedestrian traffic away from any vehicular gate No one shou...

Reviews: