A
A
CCESSORY
CCESSORY
C
C
ONNECTIONS
ONNECTIONS
R
ADIO
R
ECEIVER
C
ONNECTIONS
:
Radio Controls may be connected to the Radio Inputs to control the gate operator. When a Radio Control is active, the Radio
LED will light.
M
AG
L
OCK
& S
OLENOID
L
OCK
C
ONNECTIONS
:
Magnetic and Solenoid Locks may be connected to the controller and utilize a 2 second delay on open to help dissipate
magnetic current or solenoid power for smoother openings.
Radio Input:
1. Allows Radio Controls to activate the gate and provides 24VDC.
2. NOTE: Wireless Edge Sensor Receivers should be connected
to the Edge Terminals. See page 19.
Connecting Radio Receivers:
1. Connect Radio Relay to RADIO N.O. and RADIO COMMON.
2. If the Radio Receiver uses 24VDC, connect Radio Power to
RADIO PWR +24VDC and RADIO PWR -24VDC.
3. Use the following chart for standard radio connections:
Radio
Receiver
FAAC
LiftMaster
Linear
Multi-Code
+24VDC
Red Red
N.O.
Gray
Gray
Common
Gray
Gray
-24VDC
Black
Black
MagLock & Solenoid Inputs:
1. Allows Maglocks and Solenoid Locks to be connected to the
gate operator with a 2 second delay to open.
2. Maglocks use a NC relay contact. Solenoid Locks use a NO
contact.
Connecting Solenoid & Maglocks:
1. Set Master DIP Switch 10 to ON.
2. Set Slave DIP Switch 10 to ON.
3. Connect Solenoids to SOLENOID NO and SOLENOID COM.
4. Connect Maglocks to MAGLOCK NC and MAGLOCK COM.
Switch 10:
ON
Solenoid
Lock
Power
Mag
Lock
Power
DSW2000 Swing Gate Operator
22